!WARNING

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.The installation is to be in accordance with the National Electrical Code, ANSI/NFPA 70-1999 and Local Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precau- tion against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fix- tures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE: This fan is suitable for use with solid-state speed controls.

WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control Model No. UL7067RC, manufactured by Rhine Electric Co., Ltd.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by

Tools Needed for Assembly

One Phillips head screwdriver

One wire stripper

One stepladder

Six wire connectors (supplied)

Materials

Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

 

 

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be help- ful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a.Fan motor and housing assembly

b.One ceiling cover

c.One coupling cover

d.Five fan blades

e.Five blade flanges

f.One hanger bracket

g.One hanger ball/downrod assembly

h.One decorative cap

i.One finial nut

j.One lower glass

k.One adapter/light fitter assembly

l.One remote control transmitter

m.One remote control receiver

n.One loose parts bag, containing:

1.Two 1-1/4” threaded studs

2.Two knurled knobs

3.Two lockwashers

4.Six wire connectors

5.One hairpin clip

6.One clevis pin

7.Eleven 1/4-20 x 11mm pan head screws with lockwashers

8.Twenty-one 10-24 x 9mm truss head screws

9.Twenty-one fiber washers

10.Four 8-32 x 12mm pan head screws

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.

Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.

A

 

 

 

 

 

M

 

UP DN

 

 

 

 

 

 

HIGH

 

 

 

 

 

 

 

MED

 

 

 

 

 

 

 

LOW

 

 

D

 

 

J

 

OFF

 

 

 

E

L

REV

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

K

N

C

 

 

 

H

 

 

 

I

 

 

 

 

 

F

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

2

3

Page 2
Image 2
Emerson KF140TZ00 owner manual Additional Safety Instructions for Installation, Tools Needed for Assembly, Materials

KF140TZ00 specifications

The Emerson KF140TZ00 is a versatile and highly efficient refrigeration solution designed for various commercial and industrial applications. This model stands out due to its innovative technologies and robust characteristics, making it a reliable choice for businesses that require consistent performance in temperature control.

One of the key features of the KF140TZ00 is its advanced compressor technology. Equipped with a highly efficient scroll compressor, this unit minimizes energy consumption while maximizing cooling performance. The compressor design contributes to reduced noise levels and extended reliability, ensuring that it operates quietly and efficiently even under heavy loads.

The KF140TZ00 also incorporates state-of-the-art electronic controls, allowing for precise temperature management and real-time monitoring. These controls enable users to easily set and adjust temperature settings according to their specific needs. Furthermore, the unit is equipped with a user-friendly digital display that provides valuable information at a glance, enhancing usability and operational convenience.

To ensure optimal performance, the KF140TZ00 features a robust refrigeration system that includes high-quality evaporators and condensers. This design maximizes heat exchange efficiency, resulting in faster cooling times and lower energy costs. The unit's enhanced heat exchange capabilities also help in maintaining stable temperatures within the refrigerated space, which is essential for preserving perishable items.

Durability is another notable characteristic of the KF140TZ00. Constructed with high-grade materials, this refrigeration solution is built to withstand the rigors of demanding environments. Its corrosion-resistant exterior ensures longevity, while the sturdy internal components are designed for reliable operation over extended periods.

In terms of flexibility, the KF140TZ00 offers a range of configurations and customization options. This adaptability allows it to seamlessly integrate into various commercial setups, whether as a standalone unit or part of a larger system. Businesses can choose from multiple sizes and capacities to find the perfect fit for their refrigeration needs.

Eco-friendliness is also at the forefront of the KF140TZ00's design. Operating with environmentally friendly refrigerants, it aligns with modern sustainability goals while adhering to strict regulatory standards. This makes it an excellent choice for businesses looking to reduce their carbon footprint while maintaining high operational efficiency.

In summary, the Emerson KF140TZ00 combines advanced technology, robust construction, and user-friendly features, making it a top choice for businesses seeking reliable refrigeration solutions. Its efficiency, durability, and flexibility address the diverse challenges faced in commercial refrigeration today, ensuring that it meets the needs of various industries reliably.