4IP2046/IM
Nov 2006
2.2 Pressure Equipment Directive
The MSP400RH transmitter does not fall within the PED definition as enclosing a pressurised fluid, so is
therefore outside the scope of the Directive.
Accordingly, the Declaration of Conformity does not list the Pressure Equipment Directive.
2.3 Specifications
Materials of construction:
Transducer material PVDF
Body & cover Material Glass filled nylon
Cable gland Nylon with Nitrile cable seal
Cover seal Silicone rubber
Cover screws 316 Stainless Steel
Transducer bodyseal EPDM
Electrical
Supply voltage 12-40V dc
Output 4-20mA (3.8 - 20.5mA linear)
Relays (2) : SPST rated 1A at 24Vdc
Communications HART Digital communications (Rev. 5)
Earthing None required
Recommended Cable Two core each 0.22 mm2 min, shielded
Max. cable length 3000m
Cable resistance 0.1 Ohm per metre length max.
Cable gland Suitable for cable sizes 4mm - 8mm diameter
Operating
Range 0.45 to 11m
Temperature
Ambient -40°C to +70°C
Wetside -30°C to +70°C
Pressure -0.25 bar to 3.0 bar
Weatherproofing IP66/IP67
Certification
The MSP400 range of products are Factory Mutual (Fm) certified as Process Control Equipment meeting
basic electrical, mechanical and fire protection requirements (IP66/IP67).