PowerSure® PST Specifications

Model Number

PA350-120U

PA500-120U

POWER RATING VA/W

350VA/225W

500VA/300W

 

 

 

DIMENSIONS: in. (mm)

 

 

Unit

6.6 x 9.8 x 3.7

W x D x H

(168 x 250 x 95)

WEIGHT: lbs (kg)

 

 

Unit

11.7 (5.3)

13.5 (6.1)

 

 

 

INPUT AC PARAMETERS

 

 

Surge Protection

603J

 

 

 

Voltage Range Without

98VAC - 140VAC ±3VAC

Battery Operation

 

 

 

 

Input Power Cord

6.5 ft. (2m) attached, w/ NEMA 5-15 P

 

 

 

OUTPUT AC PARAMETERS

 

 

 

 

Output Receptacles

(3) NEMA 5-15R (orange)

 

Battery backup + surge protection;

 

(2) NEMA 5-15R (black) Surge protection

 

 

Voltage (Battery mode)

120VAC ±8%

 

 

Waveform (Battery mode)

Stepped Sinewave

 

 

Frequency

60Hz ±1Hz

PowerSure® PST Runtime Table

Typical Battery Backup Time

350VA

500VA

Pentium II w/15” Monitor

19 min.

25 min.

 

 

 

Pentium II w/17” Monitor

12 min.

18 min.

 

 

 

Pentium II w/21” Monitor

11 min.

15 min.

 

 

 

Pentium III w/15” Monitor

10 min.

14 min.

 

 

 

Pentium III w/17” Monitor

9 min.

13 min.

 

 

 

Pentium III w/21” Monitor

6 min.

9 min.

 

 

 

Pentium 4 w/15” Monitor

8 min.

11 min.

 

 

 

Pentium 4 w/17” Monitor

6 min.

9 min.

 

 

 

Pentium 4 w/21” Monitor

6 min.

 

 

 

Status indicators let you know the condition of the UPS.

All outlets are spaced to accommodate transformer plugs.

USB port offers

 

 

 

 

Data-Line protection

communication

ensures that your

to shut down if

communication

an outage ever

outlets (Phone /

exceeds battery

Fax / DSL /Internet /

capacity.

Modem) are also

 

protected.

 

 

 

Liebert Corporation

1050 Dearborn Drive

P.O. Box 29186

Columbus, Ohio 43229

800 877 9222 Phone (U.S. &

Canada Only)

614 888 0246 Phone (Outside U.S.)

614 841 6022 FAX

Via Leonardo Da Vinci 8

Zona Industriale Tognana

35028 Piove Di Sacco (PD)

Italy

39 049 9719 111 Phone

39 049 5841 257 FAX

Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong

852 25722201 Phone

852 28029250 FAX

liebert.com

24 x 7 Tech Support

800 222 5877 Phone

614 841 6755 (outside U.S.)

While every precaution has been taken to ensure accuracy

and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

© 2005 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.

All names referred to are trademarks or registered trademarks of their respective owners.

®Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.

SL-23277 (R2/06)

Printed in USA

Emerson Network Power.

The global leader in enabling business-critical continuity.

AC Power Systems

Connectivity

DC Power Systems

Embedded Power

Power Protection

Integrated Cabinet Solutions Outside Plant

Precision Cooling

Site Monitoring and Services

EmersonNetworkPower.com

Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2005 Emerson Electric Co.

Page 2
Image 2
Emerson warranty PowerSure PST Runtime Table