Dual-Compressor Module

Technical Support and Service

6.0Specifications

Table 7

Compressor Module Specifications

 

 

General Information

 

Inlet pressure range

Approximately -.75 to 25 psig

Outlet pressure range

70 to 275 psig (depends on model—see pageiv)

Mechanical Description

 

Module weight

Approximately 660 lb. (300kg)

Suction connection

1.5” NPT

Discharge connection

1.0” NPT

Sound level

 

Approximately 75 dBA @ 1 m, 60 dBA @ 10 m

Vibration

 

3 mil at 60 Hz

Minimum cold start ambient temperature 1,4

Compressor -20°F (-29°C) VFD power 14°F (-10°C)

Ambient operating temperature range 1,4

0 to 122°F (-18 to 50°C)

Module dimensions

See Figure 4 on page 6

Materials of Construction

 

Compressor - general

Cold rolled steel, aluminum, cast iron as required

Compressor bearings

Self-lubricated, sleeve type, steel backed

Oil heat exchanger

Aluminum

Oil/gas separator tank

Cold rolled steel

Tubes/fittings/skid structure

Stainless/carbon steel

Lubrication

 

 

Oil type

 

Synthetic, 15 weight, PAO (special factory-supplied blend)

System oil capacity, oz. (ml)

380 fluid ounces (11.25 liters)

Projected oil consumption 2

Approximately 40 oz. (0.9 l) / 8,000 hours at 0.25 psig suction (<5 ppm)

System Electrical (Standard)

 

Minimum VFD ambient startup temperature3,4

+14°F (-10°C)

Power supply to inverter

380 to 480VAC (50/60 Hz)

• Voltage range

 

• Input frequency range

 

 

 

Overpressure detection (outlet)

215 psig open (290 psig for SZV32)

Underpressure detection (inlet)

0.75 psig open (low pressure system)

Oil overtemperature detection

240°F (110°C) open (280°F for SZV)

Fault output to customer

Packager to establish

Run input from customer

Dry contact

Gas Medium

 

Natural gas

 

 

H

S maximum content 5

450 ppm

2

 

 

 

Moisture content 5

100% saturated, no free liquids

Inlet temperature 5

-20 to 115°F (-28 to 46°C); protection from freezing if water is present

1.If the Compressors are started at temperatures above the listed minimums and continue to run, the minimum operating temperature is 20°F (-29°C).

2.Based on sweet gas wellhead gas. Results may vary due to gas quality and site conditions.

3.Do not apply power to the VFD if ambient temperature is below this level.

4.If power is continuously supplied to the VFD when the Compressor is off, the minimum starting temperature is -4°F (-20°C).

5.Consult factory for more details and applications guidelines.

27

2006SSD-75 R4 (10/10)

Page 33
Image 33
Emerson SZV44, SZO44, SZV32, SZO56 manual Specifications Compressor Module Specifications