Model NGA2000 NDIR

Instruction Manual

748332-F April 2003

4

Main Menu

Basic controls...

Expert controls and setup...

(Operational configuration)

Technical level configuration...

(Diagnostic and manufacturing/service)

Basic level security

(expert, technical)

Enter your security code with softkeys. Security codes are set in the system setup menu in the Technical level menus.

Press five characters when Security code says READY. Press six to return to “READY”.

Security code:

54321

Basic controls

Measurement range number:

1

Range upper limit:

10 ppm

Range and functional control: LOCAL

Zero gas concentration:

0 ppm

Span gas concentration:

9.89 ppm

Ranges with valid calibration:

1&2

Calibration status:

Ready

If it won’t calibrate...

 

Status:

Ready

ZERO

 

 

Current measurement parameters

 

 

 

 

 

 

 

Measurement range number:

1

 

 

 

Current measurement parameters

 

 

Range change control:

Local

 

 

 

Response time:

2.0 Secs

PARMS

 

Measured Gas:

CO2

 

MORE

 

Sample flow:

1000 ml/min.

 

 

Linearization mode:

ON

 

 

 

Sample pressure:

12.3 kPa

 

 

Gas Measurement Setup:

ON

 

 

 

Case Temperature:

55.3!C

 

 

 

 

 

Analyzer operational state:

Normal

 

 

 

 

 

 

 

 

 

 

 

 

Analyzer alarm state:

Normal

 

 

 

 

 

 

 

Alarms report:

Failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Expert controls and setup

 

Technical configuration menu

Expert analyzer controls...

 

System set up...

Auxiliary module controls...

 

Service menus...

System set up...

 

Diagnostic menus...

Analyzer module set up...

 

Other module diagnostic menus...

Auxiliary module set up...

 

Listing of all modules...

...Local I/O set up

 

 

 

 

 

Expert and Technical menus follow in succeeding flow charts.

SPAN

Analyzer Zero

Are you sure?

You must have zero gas flowing through the analyzer.

This control does NOT control any auto- cal. Module bound to this analyzer!

If you are sure, press ZERO again now. Press left arrow key when you are done.

Calibration status:Ready

Error message for last zero: 24-08-94

Analyzer Span

Are you sure?

You must have zero gas flowing through the analyzer.

This control does NOT control any auto- cal. Module bound to this analyzer!

If you are sure, press SPAN again now. Press left arrow key when you are done.

Calibration status:Ready

Error message for last zero: 24-08-94

If it won’t calibrate...

Check that you are flowing the correct gas, and the gas concentration is what it is supposed to be. Make sure that the reading is stable before starting. If you have changed the range fullscale value or any linearizer coefficients, or enabled or disabled it, or done anything else that would affect how it measures the gas, you may have made it hard for the analyzer to calibrate. If so, manually adjust the coefficients until the readings are close to correct, and try again.

Figure 3-9. Display Screens (1 of 5)

Rosemount Analytical Inc. A Division of Emerson Process Management

Maintenance and Service 3-9