Empire Comfort Systems CIVF-25-2 Installing Optional CIB-2 Blower, Fan Control, Wiring

Models: CIVF-25-2

1 20
Download 20 pages 53.84 Kb
Page 19
Image 19

OPTIONAL BLOWER CIB-2 Unvented Room Heater CIVF-25

Installing Optional CIB-2 Blower

1.Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance.

2.Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the appliance.

3.Place the large diameter holes in the keyholes over and behind the

(4) hex-head screws that were loosened in Step 1. Push inward on the blower assembly to lock the keyholes into position behind the screws. Tighten (4) hex-head screws to secure blower assembly to exterior, bottom of the appliance.

4.Remove wire channel from rear cover by removing (4) hex-head screws. Note: If optional blower is being installed during initial installation of appliance, the wire channel will not be attached to casing back. (Refer to Installation of Wire Channel Assembly, Page 9)

5.Remove casing top and casing front from outer casing.

6.If optional stone inlay is installed in casing top, remove the 12" x 19 3/8" heat shield from the heat exchanger top by removing (4) 1/2" hex-head screws.

7.When facing the rear of the appliance, insert fan control shield between rear cover and inner body of appliance on the left side of the rear cover.

8.Attach fan control shield to top of inner body with (2) #10 x 1/2" screw provided in hardware package.

9.If applicable, attach 12" x 19 3/8" heat shield to heat exchanger top with (4) 1/2" hex-head screws from Step 6.

10.Place the casing top onto the outer casing. The casing top nests into the outer casing.

11.Attach fan control to FLAT, fan control bracket (Part 9A, Page 20) with (2) 6 x 1/4" screws provided in hardware package.

12.Attach fan control with bracket onto the wire channel by using (2) 8 x 1/4" screws provided in hardware package.

13.Route wires from fan control and ON/OFF/REMOTE switch within wire channel.

14.When facing the rear of the appliance, align and insert fan control with bracket into 1 3/8" x 2" opening on the left side of the rear cover.

15.Attach wire channel to rear cover by using (4) hex-head screws removed in Step 4. (Refer to Installation of Wire Channel Assembly, Page 9)

16.Insert AUTO/OFF/ON switch into rectangular notch on valve bracket. Be sure to insert AUTO/OFF/ON switch with letters (words) upright. (See wiring diagram)

17.Attach 1/4" push-on terminal from blue wire on the fan control to the AUTO (top) tab on the switch.

18.Attach 1/4" push-on terminal from black wire to the OFF (middle) tab on the switch.

19.Attach 1/4" push-on terminal from white wire on the fan control to the ON (bottom) tab on the switch.

20.Installation of optional CIB-2 blower is completed.

Fan Control

The fan control is a non-adjustable automatic type. The fan control will require between 5 and 10 minutes of main burner operation before the fan control "closes" and activates the blower. The blower will continue to run between 5 and 10 minutes after the main burner shuts off, before the fan control "opens" and deactivates the blower.

Wiring

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA No. 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screws. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING:

Unplugging of blower accessory will not stop the heater from cycling. To shut heater off: Turn temperature dial or thermostat to lowest setting. Turn knob on gas control to "OFF", depressing slightly. Do not force.

R-3451

Page 19

Page 19
Image 19
Empire Comfort Systems CIVF-25-2 installation instructions Installing Optional CIB-2 Blower, Fan Control, Wiring

CIVF-25-2 specifications

Empire Comfort Systems CIVF-25-2 is a distinguished wall-mounted vent-free gas fireplace that brings warmth and ambiance to any space. This elegant unit is designed to efficiently deliver heat while offering a stylish aesthetic that enhances home décor. The CIVF-25-2 stands out due to its unique combination of features, technologies, and characteristics.

One of the main features of the Empire Comfort Systems CIVF-25-2 is its adjustable air shutter system. This allows users to control the flame height and intensity, providing the flexibility to create the perfect atmosphere for any occasion. The fireplace is equipped with a state-of-the-art burner system that ensures a clean and efficient burn, maximizing heat output while minimizing emissions.

The CIVF-25-2 operates using either natural gas or propane. This versatility allows homeowners to choose the fuel source that best fits their needs. The unit also features a safety pilot system that includes an automatic shut-off function, ensuring peace of mind for users. This pilot system is designed to operate even during power outages, making it a reliable source of heat during adverse weather conditions.

In terms of aesthetics, the CIVF-25-2 is available in various styles and finishes, allowing it to complement any interior design. The elegant front glass creates a stunning visual impact while also providing a safe barrier from the flames, making it ideal for households with children or pets. Additionally, the fireplace’s minimalist design ensures it can fit seamlessly into smaller spaces without sacrificing heat output.

Another noteworthy characteristic is the easy installation process. The vent-free design means that it does not require a traditional chimney or venting system, which simplifies the setup and reduces installation costs. This feature allows homeowners to enjoy the benefits of a fireplace without the complexities typically associated with traditional fireplaces.

In summary, the Empire Comfort Systems CIVF-25-2 offers a blend of modern technology, safety features, and stylish design. With its adjustable air shutter, versatile fuel options, safety pilot system, and easy installation, it is an excellent choice for anyone looking to enhance their home with the warmth and charm of a gas fireplace.