VFDM(18,24,30)LB LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electrical switch; Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service tech- nician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

GAS CONTROL KNOB SHOWN IN “OFF” POSITION

for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 2 through 6.

If knob does not pop up when released, stop and im- mediately callyou service technician or gas supplier

CONTROL KNOB INDICATOR

3.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas,

 

go to the next step.

 

THERMOCOUPLE

 

 

 

4.

Find pilot - the pilot is located in

(LPG)

 

front of the rear log.

 

PILOT

 

 

THERMOCOUPLE

5.

Turn manual gas control knob

(NAT)

 

 

counterclockwise

to

 

 

"PILOT."

 

 

6.Push in manual gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit (or use a match to light). Continue to hold the control knob in

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

7.Three heat settings can be selected by slightly depressing the manual gas control knob and turning the manual gas control

knob counterclockwise to 1, 2 or 3.

8.CAUTION! WHen the manual gas control knob has been turned to desired heat setting, ensure that the manual gas control knob is locked into that heat setting and cannot be turned without being depressed. If the manual gas control knob is in mid-position, between heat settings, incomplete combustion will take place, causing odor and may produce gas leakage or carbon monoxide.

TO TURN OFF GAS TO APPLIANCE

1.Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

Page 20