Empire Comfort Systems VFDM30LBN-1, VFDT24LBN-1 Combustible Material, Fireplace Preparation

Models: VFDM18LBN-1 VFDM24LBN-1 VFDT18LBN-1 VFDR24LBN-1 VFDR18LB10N-1 VFDR30LBN-1 VFDR18LB10P-1 VFDT18LBP-1 VFDT30LBN-1 VFDR18LBN-1 VFDT24LBN-1 VFDR24LBP-1 VFDR18LBP-1 VFDR30LBP-1 VFDM30LBN-1

1 32
Download 32 pages 49.37 Kb
Page 10
Image 10

COMBUSTIBLE MATERIAL

Do not attach combustible material to the mantel of your fireplace. This is a fire hazard.

No greeting card, stockings or ornamentation of any type should be placed on or attached to the fireplace. This is a heating appliance. The flow of heat can ignite combustibles.

Figure 7

Figure 8

FIREPLACE PREPARATION

Turn off gas supply to fireplace or firebox.

Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other obstructions.

Have this cleaning performed annually after installation.

Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

Install and operate the appliance as directed in this manual.

FOR FACTORY BUILT FIREPLACES

FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORA- TIVEAPPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES

 

 

Appliance Input Rate (BTU/hr)

 

 

20

 

30

 

40

Chimney

 

Minimum Opening** (sq. in.)

 

Height* (ft)

 

 

 

 

 

10

11.3

 

16.6

 

22.1

15

8.6

 

12.6

 

17.3

20

7.5

 

10.8

 

14.5

25

6.6

 

9.6

 

12.6

30

6.2

 

9.1

 

11.3

35

5.7

 

8.0

 

10.8

40

5.3

 

7.5

 

10.2

FOR MASONRY BUILT FIREPLACES

FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORA- TIVEAPPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES

 

 

Appliance Input Rate (BTU/hr)

 

 

20

 

30

 

40

Chimney

 

Minimum Opening** (sq. in.)

 

Height* (ft)

 

 

 

 

 

6

17.6

 

25.7

 

33.8

8

16.5

 

23.7

 

31.2

10

15.1

 

21.7

 

28.7

15

14.1

 

19.9

 

26.1

20

12.9

 

18.5

 

23.7

30

12.2

 

16.9

 

21.6

*Height is from hearth to top of chimney and the minimum height is 6 feet.

**Chart shows minimum opening (sq. in.) for given height and input rate.

*Height is from hearth to top of chimney and the minimum height is 10 feet.

**Chart shows minimum opening (sq. in.) for given height and input rate.

Page 10

23099-1-0707

Page 10
Image 10
Empire Comfort Systems VFDM30LBN-1, VFDT24LBN-1, VFDR30LBN-1, VFDR24LBN-1 Combustible Material, Fireplace Preparation