C-5. ELECTRICAL CONNECTION.
The VFFB36/42D with optional fan requires 120 VAC electrical hookup to the electrical box (installed).
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).
A factory installed electrical box is located on the lower right hand side of the fireplace. Wiring must be fed to the electrical box and attached to the receptacle that you must provide. Remove the knockout in the installed junction box to accept wiring into the junction box. Install a UL listed cable clamp (not supplied) in the knockout hole. Leave approximately 6” of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to opposite side of receptacle.
The ground wire should be attached to the green (neutral) screw.
Install the receptacle into the metal box. Attach cover plate.
JUNCTION
BOX
NEUTRAL |
|
| |
| WH | ITE | GROUND |
| |||
BLACK |
|
Fig. 7. Electrical junction box connection.
C-6. OPTIONAL FRESH AIR INTAKE KITS
MODEL: VFFB-AK-36
Installation of our 6" fresh air intake kit is simple and easy to complete. This system MUST BE installed before the fire- place is enclosed with finishing material.
Install model
Cooler outside air will mix with room air, circulating around the firebox to reduce the heat output and bring heated, fresh air into the house to provide a more positive balance.
INSULATED
DUCT
Fig. 8. Fresh air intake kit.