Empire Comfort Systems VFFB-42D, VFFB-36D dimensions Clearances

Models: VFFB-42D VFFB-36D

1 16
Download 16 pages 29.96 Kb
Page 3
Image 3
1. CLEARANCES.

 

FINISHED

VFFB-36/42

WALL

 

 

8”

42” MIN.

STAND-OFF

FLAT

MANTEL

SHELF

3”

11” MIN. CLEARANCE

6” FROM

INSIDE EDGEHOOD OF OPENING

TOP VIEW

FINISHED

WALL

5”

MANTEL

TRIM

Fig. 1. Clearances to combustibles.

1. CLEARANCES.

OUTER CASING

MANTEL TRIM

FIREBOX FIRE BOX

16" ON 36 19" ON 42

5”

NON-COMBUSTIBLE

MATERIAL

Sidewall Clearances: The clearance from the inside of the fireplace to any combustible wall should not be less than 6”.

Fireplace Side and Back Clearances: The fireplace outer casing sides and back have zero clearance to combustibles.

Ceiling Clearances: The ceiling height should not be less than 42” from the top of the fireplace opening.

Mantel Clearances: Vent free fireplace models must use the hood supplied with the fireplace. If a combustible mantel is installed, it must meet the clearance requirements detailed above.

Grate Clearance: The minimum clearance between the front legs of the grate and front edge of the fireplace is 2”.