INSTALLATION
Wiring
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a
Thermostat Installation
The thermostat should be installed in the same room as the furnace 4’ (1.2m) to 5’ (1.5m) above the floor and away from another heat source (cooking stove, hot water heater, etc.) including walls and doorways with a heat source in an adjoining room. Do Not Install Thermostat on Outside Wall.
Insulated Vent Enclosure
Vented wall furnaces installed in buildings with flat roofs can have poor venting. The cold vent pipe will have a delay in proper venting and cause the wall furnace to shut “OFF” by the vent safety switch. To prevent delayed venting as well as condensation of flue products an insulated vent enclosure is recommended.
Use type B vent pipe and maintain at least a one inch (25mm) clearance to combustibles.
Use metal thimble to protect vent pipe as it passes through combustibles.
Vent Safety Shutoff System
This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system.
Warning: Operation of this wall furnace when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.
This furnace is equipped with a manual reset vent safety switch. The manual reset vent safety switch will cause gas flow to the main burners to “shut off” due to improper venting or a blocked flue.
To reset the manual reset vent safety switch:
1.Remove upper front panel.
2.Depress red manual reset button. The manual reset vent safety switch is located on the draft diverter.
3.Replace upper front panel.
If the manual reset vent safety switch continues to “shut off” the gas flow to the main burners a qualified service person must be contacted to inspect for improper venting, blockage in the vent pipe or the manual reset vent safety switch for being defective.
(3m)
(.6m)
(3m)
More than 10”
Figure 8 | Figure 9 | Figure 10 |
|
|
Page 9 |