S8600H TROUBLESHOOTING GUIDE

Green LED Status Codes

Green LED

 

 

 

Flash Code

 

 

 

(X + Y)a

Indicates

Next System Action

Recommended Service Action

OFF

No “Call for Heat”

Not applicable

None

Flash Fast

Startup-Flame sense calibration

Not applicable

None

Heart Beat

Normal operation

Not applicable

None

3

Recycle

Initiate new trial for ignition. Flash code

If system fails to light on next trial for

 

- Flame failed during run

will remain through the ignition trial

ignition, check gas supply, pilot burner,

 

 

until flame is proved.

flame sense wiring, contamination of

 

 

 

flame rod, burner ground connection.

4

Flame sensed out of sequence

If situation self corrects within 10 sec-

Check for pilot flame. Replace gas valve

 

 

onds, control returns to normal sequence.

if pilot flame present. If no pilot flame,

 

 

If flame out of sequence remains longer

cycle “Call for Heat.” If error repeats,

 

 

than 10 seconds, control goes to Flash

replace control.

 

 

code 6 + 4 (see below).

 

7

Flame sense leakage to ground

Control remains in wait mode. When

Check flame sense lead wire for damage

 

 

the fault corrects, control resumes nor-

or shorting. Check that flame rod is in

 

 

mal operation after a one minute delay.

proper position.

 

 

 

Check flame rod ceramic for cracks,

 

 

 

damage or tracking.

8

Low secondary voltage supply -

Control remains in wait mode. When

Check transformer andAC line for proper

 

below 15.5 Vac)

the fault corrects, control resumes nor-

input voltage to the control. Check with

 

 

mal operation after a one minute delay.

full system load on the transformer.

6 + 2

Failed trial for ignition resulting

Remain in lockout until “Call for Heat”

Check gas supply, pilot burner, spark

 

in lockout

is cycled.

and flame sense wiring, flame rod con-

 

 

 

taminated or out of position, burner

 

 

 

ground connection.

6 + 3

More than 5 flame failures during

Remain in lockout until “Call for Heat”

Check gas supply, pilot burner, flame

 

run on the same “Call for Heat”

is cycled.

sense wiring, contamination of flame

 

resulting in lockout

 

rod, burner ground connection.

6 + 4

Flame sensed out of sequence -

Control waits until flame is no longer

Check for pilot flame. Replace gas valve

 

longer than 10 seconds

sensed and then goes to soft lockout.

if pilot flame present. If no pilot flame,

 

 

Flash code continues. Control auto re-

cycle “Call for Heat.” If error repeats,

 

 

sets from soft lockout after one hour.

replace control.

ON

Soft lockout due to error detected

Control auto resets from soft lockout af-

Reset by cycling “Call for Heat.” If er-

 

during self check sequences

ter one hour.

ror repeats, replace the control.

aFlash Code Descriptions:

-Flash Fast: Rapid blinking

-Heartbeat: Constant 1/2 second bright 1/2 second dim cycles

-A single flash code number signifies that the LED flashes X times at 2Hz, remains off for two seconds, and then repeats the sequence.

-X + Y flash codes signify that the LED flashes X times at 2Hz, remains off for two seconds, flashes Y times at 2Hz, remains off for three seconds, and then repeats the sequence.

12429-10-0408

Page 15

Page 15
Image 15
Empire Products FAW-55IP installation instructions Green LED Status Codes

FAW-55IP specifications

The Empire Products FAW-55IP represents a significant advancement in the realm of portable air conditioning systems. This model blends efficiency, portability, and modern technology to provide an unparalleled cooling experience. Designed for both residential and commercial use, the FAW-55IP is ideal for spaces that require reliable climate control without the need for permanent installation.

One of the standout features of the FAW-55IP is its impressive cooling capacity. With a powerful 55,000 BTU rating, it can effectively cool large areas, making it perfect for workshops, retail spaces, and larger rooms in homes. The unit is equipped with a high-efficiency compressor that not only cools effectively but also provides energy savings, making it an eco-friendly choice.

The FAW-55IP utilizes advanced inverter technology, allowing for variable speed operation. This means that the unit can adjust its cooling output based on the ambient temperature, ensuring a more consistent temperature control while minimizing energy consumption. This feature significantly reduces electricity costs compared to traditional air conditioning units.

Portability is another key aspect of the FAW-55IP. With built-in caster wheels and a lightweight design, this air conditioning unit can be easily moved from one room to another, allowing for versatility in its use. Whether you need to cool down a living space during hot summer months or provide comfort in a temporary workspace, this model meets a variety of cooling needs.

The user-friendly digital control panel makes operation simple, with options for adjusting the temperature, fan speed, and mode settings. Additionally, the unit comes with a remote control, allowing users to make adjustments from a distance. Its programmable timer function adds to the convenience, enabling users to set the unit to operate on a schedule that suits their lifestyle.

Furthermore, the FAW-55IP includes advanced filtration technology that helps enhance indoor air quality. The washable filter captures dust, allergens, and other particles, ensuring that the cooled air is clean and fresh. This is particularly beneficial for those with allergies or respiratory conditions, as it helps to create a healthier indoor environment.

In summary, the Empire Products FAW-55IP stands out due to its robust cooling capacity, efficient inverter technology, portability, user-friendly controls, and advanced filtration system. As such, it represents an excellent investment for anyone looking to improve their indoor climate comfort while keeping energy consumption in check.