APPENDIX A:
ALTERNATE FLOOR PROTECTION
All floor protection materials must be
The easiest means of determining if a proposed alternate floor material meets requirements listed in this manual is to follow this procedure.
1.Convert the specification to
a.If
needed.
b.If
c.If
2.Determine the
a.Use the formula in Step 1 to convert values not expressed as “R”.
b.For multiple layers, add
3.If the overall
EXAMPLE:
The specified floor protector should be 3/4” thick material with a
1/8” mineral board witha
Step A. Use formula above to convert specifications to
Step B. Calculate R of proposed system. 4” brick of
R brick = 1/C = 1/1.25 = 0.80.
1/8” mineral board of k = 0.29 therefore R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board= 0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of 0.893. Since R is greater than required, the system is acceptable.
Definitions:
Thermal conductance = |
|
|
|
| ||
| Btu |
| = | W |
|
|
C = (hr)(ft2)(F) |
| (m2)(K) |
| |||
Thermal conductivity = |
|
|
|
| ||
k = | Btu | = |
| W | = | (Btu) |
(hr)(ft2)(F) |
|
| (m2)(K) |
| (hr)(ft)(F) | |
Thermal resistance = |
|
|
|
|
| |
| Btu |
| = | (m2)(K) | = (Btu)(inch) | |
R = (hr)(ft2)(F) |
| W |
| (hr)(ft2)(F) |
FOR THE JØTUL F 3 CB WOOD STOVE REQUIRES FLOOR PROTECTION WITH A MINIMUM INSULATING
R VALUE OF 1.1.
ALCOVE INSTALLATION REQUIRE A MINIMUM R VALUE OF 1.1. (IF A UL/ULC or WHI LISTED HEARTH PAD IS NOT USED.)
20