INSTALLATION

INSTALLATION

IFTHISSOLIDFUELROOMHEATERISNOTPROPERLY INSTALLEDAHOUSE FIRE MAYRESULT. FORYOUR SAFETY, FOLLOWTHEINSTALLATION DIRECTIONS. CONTACTTHELOCALBUILDINGORFIREOFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.

Reminder:

Your local officials have final authority in determining if a proposed installation is acceptable. Any requirement, that is requested by the local authority having jurisdiction, that is not specifically addressed in THIS manual, defaults to NFPA 211, and local codes in the U.S. or in Canada, CAN/ CSA-B365-M and local codes.

INSTALLING THE VENTING

The F 3 CB can be vented from the top, the rear or from either the right or left side. Follow the instructions below for the desired venting location.

TOP EXIT VENTING

When top exit venting is desired, use a 3mm allen wrench to remove the two set screws that secure the top casting to the sides of the stove and lift off the top casting. Lay the top casting on a flat surface upside down and remove the 10mm bolt from the traverse bar and remove the smoke outlet cover.

Reinstall the top casting, be sure to secure with the two set screws that were removed. See figure 1.

REAR EXIT VENTING

When rear exit venting is desired it will be necessary to “knock-out” the vent hole from the rear casting.

Remove the top casting of the stove by removing the two 3mm set screws that secures the top to the sides. The set screws are located on the outside of the stove on the top of each side panel.

Using a 10mm wrench remove the double rear heatshields from the back of the stove. Remove the front door to avoid damage to the glass. Reminder: loss of the door washer will result in improper door alignment when reinstalling the door.

Using a claw hammer or a small sledge hammer strike the CENTER of the 6” “knock-out” disc from the OUTSIDE of the stove. The “knock-out” disc will break into four wedges and may need to be tapped out. Touch up any remaining sharp edges with a file or hand grinder.

NOTE: The IVORY F 3 CB’s ARE REAR VENTED FROM THE FACTORY. IT IS NOT NECESSARY TO “KNOCK-OUT” THE REAR CASTING OF THE STOVE. HOWEVER, IF TOP EXIT IS DESIRED IT IS NECESSARY TO INSTALL A SMOKE OUTLET COVER ON THE REAR OUTLET OF THE STOVE.

SPACERS

UPSIDE DOWN

STOVE PIPE STOP

TOP CASTING

 

HEATSHIELD WITH

 

LISTING LABEL

 

SHOULD BE

 

INSTALLED ON THE

FIGURE2

OUTSIDE

 

TRAVERSE BAR SECURING

STOVE PIPE STOP

 

SMOKE OUTLET COVER

 

TO TOP CASTING

FIGURE1

Reinstall the top casting and front door, remembering the washer. The two rear heatshields MUST be reinstalled on the stove. Remove the metal cover plates from the heatshields and reinstall. Reminder: there is a small nut used as a spacer between the two heatshields. See figure 2.