WALL SHIELDS FOR CLOSE CLEARANCE
WALL SHIELD
•Must be 30” wide and
centered behind the stove
•Must be 1” off the wall and 1” off the floor.
•With standard legs, the shield must be 32” high.
•With optional short legs, the shield must be 30” high.
WALL SHIELD
•Must be 1” off the wall and 1” off the floor.
•With standard legs, the shield must be 40” high.
•With optional short legs,
the shield must be 38” high.
•Both shields MUST
extend and join in the corner
WALL SHIELD
•Must be 1” off the wall and 1” off the floor.
•With standard legs, the shield must be 40” high
•With the optional short
legs, the shield must be 38” high.
•Both shields must
extend and join in the corner.
COMBUSTIBLE
WALL
&20%867,%/( :$//
The wall shield must extend a minimum of 4” (102mm) past the side of the stove.
The wall shield must extend a minimum of 4” (102mm) past the ash lip of the stove.
&20%867,%/(
WALL
The wall shield must extend a minimum of
12” (305mm) past the front corner of the stove.
The wall shield must |
|
extend a minimum of 12” (305mm) | |
past the front corner of the stove. |
12