Jotul F 3 Wall Shields For Close Clearance, Must be 30” wide and centeredbehind the stove

Models: F 3

1 21
Download 21 pages 15.31 Kb
Page 12
Image 12
WALL SHIELDS FOR CLOSE CLEARANCE

WALL SHIELDS FOR CLOSE CLEARANCE

WALL SHIELD

Must be 30” wide and

centered behind the stove￿￿￿

Must be 1” off the wall and 1” off the floor.

With standard legs, the shield must be 32” high.

With optional short legs, the shield must be 30” high.

WALL SHIELD WALL SHIELD

Must be 1” off the wall and 1” off the floor.￿

With standard legs, the shield must be 40” high.￿

With optional short legs,

the shield must be 38” high.￿

Both shields MUST

extend and join in the corner￿￿

WALL SHIELD •Must be 30” wide and

Must be 1” off the wall and 1” off the floor.￿

With standard legs, the shield must be 40” high￿￿

With the optional short

legs, the shield must be 38” high.￿

Both shields must

extend and join in the corner.￿

WALL SHIELD COMBUSTIBLE

WALL

Manual background &20%867,%/(￿ :$//￿

The wall shield must extend a minimum of 4” (102mm) past the side of the stove.

The wall shield must extend a minimum of 4” (102mm) past the ash lip of the stove.

Manual background &20%867,%/(￿

WALL

The wall shield must extend a minimum of

12” (305mm) past the front corner of the stove.￿

The wall shield must

 

extend a minimum of 12” (305mm)

￿

past the front corner of the stove.￿

12

Page 12
Image 12
Jotul F 3 operating instructions Wall Shields For Close Clearance, Must be 30” wide and centeredbehind the stove