Jotul F 3 CB WOODSTOVE CLEARANCES, Stove Clearances, Unprotected Surfaces, Protected Surfaces

Models: F 3

1 21
Download 21 pages 15.31 Kb
Page 11
Image 11
F 3 CB WOODSTOVE CLEARANCES*

F 3 CB WOODSTOVE CLEARANCES*

STOVE CLEARANCES

UNPROTECTED SURFACES

PROTECTED SURFACES

TOP VENT/VERTICAL

 

 

 

per NFPA 211 or CAN/CSA-B365-M

 

SIDE

REAR

CORNER

SIDE

REAR

CORNER

Rear heatshield with

24"

25"

18"

10"

14"

10"

Single wall pipe

610 mm

635 mm

460 mm

255 mm

355 mm

255 mm

Rear heatshield with

18"

10"

14"

6"

6"

6"

Double wall pipe or shields

460 mm

255 mm

355 mm

150 mm

150 mm

150 mm

 

 

 

STOVE CLEARANCES

UNPROTECTED SURFACES

PROTECTED SURFACES

REARVENT/HORIZONTAL

 

 

 

per NFPA 211 or CAN/CSA-B365-M

 

SIDE

REAR

CORNER

SIDE

REAR

CORNER

Rear heatshield with

24”

25”

20”

10”

25”

18”

Single wall pipe

610 mm

635 mm

510 mm

255 mm

635 mm

460 mm

Rear heatshield with

18”

14”

17”

6”

6”

6”

Double wall pipe or shields

460 mm

355 mm

430 mm

150 mm

150 mm

150 mm

 

 

 

CONNECTOR

UNPROTECTED SURFACE

PROTECTED SURFACE

CLEARANCES

 

 

 

per NFPA 211 or CAN/CSA-B365-M

 

 

 

 

 

 

Single wall pipe-vertical installations

18" (460mm)

 

6" (150mm)

 

Double wall pipe-vertical installations

pipe mfgr. listing

 

pipe mfgr. listing

Single wall pipe-horizontal installations

18” (460mm)

 

9” (230mm)

Double wall pipe-horizontal installations

pipe mfgr. listing

 

pipe mfgr. listing

VERY IMPORTANT:

Top Vent - Vertical: assumes the connector pipe runs from the top of the stove and travels vertically. If top vented to a horizontal run, the stove position is dictated by the connector pipe clearances.

Rear Vent - Horizontal: assumes the connector pipe extends from the rear of the stove and travels horizontally to the chimney. If rear vented to a vertical run, the stove position is dictated by the connector pipe clearances.

Dimensions in Inches represent U.S. requirements. Dimensions in Millimeters represent Canadian requirements.

WALL PROTECTION IS DISCUSSED IN FURTHER DETAIL ON PAGE 12 OF THIS MANUAL.

MANTEL CLEARANCES

 

A

C

B

D

 

A = Top to Mantel

34”

860mm

B = Top to Top Trim

20”

510mm

C = Side to Side Trim

13”

330mm

D = Side to Side Wall:

24’

610mm

11