Empire Products FAW-55IP installation instructions Installation, Installing Optional Rear Outlet

Models: FAW-55IP

1 20
Download 20 pages 40.38 Kb
Page 6
Image 6
Installing Optional Rear Outlet

INSTALLATION

Installing Optional Rear Outlet

Rear outlet kit, 10” (254mm) boot assembly with register, ROK-1 for warm air discharge into an adjoining room.

Attention: Before furnace is attached to the wall, the wall opening for the rear outlet must be cut, in addition to removal of the outer and inner casing knockouts on furnace.

1.The wall opening measurements for the rear outlet are the following.

A.From floor to bottom of wall opening is 14 3/4” (375mm).

B.From bottom of wall opening to top of wall opening is 8 1/2” (216mm) .

C.Wall opening width is 12 1/8” (308mm).

2.Remove outer casing knockout from outer casing back.

3.Remove inner casing knockout from inner casing.

4.Attach furnace to wall (see Attaching Furnace to Wall).

5.Align clearance holes on 8” x 12” (203mm x 305mm) boot with screw holes on outer casing back and mark boot to be flush with wall surface. Remove boot and cut to proper length.

6.Attach 8” x 12” (203mm x 305mm) boot to outer casing back with (6) #10 x 1/2” (13mm) screws provided.

7.Align clearance holes on 6” x 10” (152mm x 254mm) duct with screw holes on inner casing and mark duct to be 2 1/4” (57mm) shorter than 8” x 12” (203mm x 305mm) boot. Remove duct and cut to proper length.

8.Attach 6” x 10” (152mm x 254mm) duct to inner casing with

(6) #10 x 1/2” (13mm) screws provided.

9.Insert rear register into 8” x 12” (203mm x 305mm) boot. Attach rear register to wall with (2) #10 x 1” (25mm) screws provided.

ALL CONNECTIONS MUST BE MECHANICALLY

MADE AND LISTED CLERANCES MAINTAINED

2 PIECE VENT ENCLOSURE

CUT TO THE PROPER LENGTH*PARTS LISTED ARE TO BE PURCHASED LOCALLY

SPACER STRAP*

MOUNTING HOLE

BASE PLATE*

BASE PLATE

GASKET

Figure 1

VENT CENTER TO COMBUSTIBLES

4”(102mm) OVAL TYPE “B”

CONNECTION

MINIMUM CLEARANCE 9/16” (40mm)

 

 

7/1/2” (191mm) MINIMUM

 

CLEARANCE TOP TO

 

COMBUSTIBLES

VENT ENCLOSURE

 

DV-651 or DV-665 or

 

DV-666

 

 

SIDE OUTLET

 

KIT PART SOK-1

MINIMUM CLEARANCE

 

TO COMBUSTIBLES

 

18”(457mm)

 

Register

 

Part SOR-1

 

6 5/8 (168mm)

 

WALL TO VALVE INLET

4”(102mm) MINIMUM

 

3”(76mm) TO CENTER OF

CLEARANCE TO

½”(13mm) INLET ELBOW

COMBUSTIBLES

REAR OUTLET

CONTROL VALVE INLET

 

3 3/4”(95mm) FLOOR TO

REGISTER KIT #ROK-1

 

Figure 2

 

(102mm)

(102mm)

(102mm)

(140mm)

(140mm)

(406mm)

 

3 1/4” (83mm)

 

11 ½”(292mm)

Figure 3

Figure 3A

Page 6

12429-10-0408

Page 6
Image 6
Empire Products FAW-55IP installation instructions Installation, Installing Optional Rear Outlet