Enerco HST45 owner manual Burner does not Light, Burner does not Stay LIT

Models: HST45

1 24
Download 24 pages 31.37 Kb
Page 21
Image 21

BURNER DOES NOT LIGHT

Possible Cause

Air in the gas line.

Improper gas inlet pressure.

Gas valve does not open.

Low gas outlet pressure.

BURNER DOES NOT STAY LIT

Possible Cause

Damaged wires between DSI module and electrode.

Faulty DSI module

Damaged Electrode

Try This….

Purge gas lines.

Check gas inlet pressure at the 1/8” NPT plugged tap. Gas inlet pressure should be as follows:

Natural Gas: 5.0”w.c. min.; 10.5” max.

LP Gas: 11”w.c. min.; 13.0” max.

If gas inlet pressure does not meet inlet pressure requirements contact the gas company.

Check for 24V across valve terminals.

Check Shutoff On Valve.

IF NO: Check wiring between the ignition module and the valve. Repair/replace wires as required. If wiring is OK, replace ignition module. IF YES: Replace gas valve.

Check gas manifold pressure. Measure manifold pressure at the pressure tap on the gas valve.

Check gas manifold pressure. Measure manifold pressure at the pressure tap on the gas valve. Natural Gas: 4.0” w.c. LP Gas: 10.0” w.c. If manifold pressure does not meet requirements, adjust valve outlet pressure with the adjustment screw on the valve. NOTE: Proper inlet gas pressure must be verified before performing outlet pressure testing.

Try this…..

Replace wires as required.

Replace DSI module.

Replace Electrode

Enerco Group, Inc., Gas-Fired Low-Intensity Infrared Heater

21

Operating Instructions and Owner’s Manual

Page 21
Image 21
Enerco HST45 owner manual Burner does not Light, Burner does not Stay LIT