Enerco HST45 Technical Specifications, Side View End View, Heater Specifications, Length

Models: HST45

1 24
Download 24 pages 31.37 Kb
Page 5
Image 5

Technical Specifications:

 

Length

111/2"

1" Max.

 

Reflector

Burner Box

Suspension Points

Heat

 

 

Exchanger

131/2 "

9"

- Side View -

- End View -

 

Leading Particulars

 

Model No.

BTU/hr

Weight

Length

MHT- 45

45,000

96 lbs.

10’

 

 

 

 

HST- 45

45,000

96 lbs.

10’

HEATER SPECIFICATIONS

Electrical

Rating: 120VAC, 60Hz, single phase, 1 amp

Connection: 3 pin molded plug

Gas Inlet Connection

Connection ½” Male NPT

Gas Inlet Pressure

The minimum inlet gas supply pressure for the purpose of input adjustment.

Natural Gas:

Minimum - Inlet 5.0” w.c.

Maximum - Inlet 10.5” w.c.

LP Gas (propane):

Minimum - Inlet 11.0” w.c.

Maximum – Inlet 13.0” w.c.

Manifold Pressure

Natural Gas: 4.0” w.c.

LP Gas (propane): 10.0” w.c.

VENTING SPECIFICATIONS

Vent/Flue

Length – 25 feet (Maximum) 5 feet (Minimum)

Flue Pipe – 3.0” diameter

Vent Pipe – 3” diameter

Enerco Group, Inc., Gas-Fired Low-Intensity Infrared Heater

5

Operating Instructions and Owner’s Manual

Page 5
Image 5
Enerco HST45 Technical Specifications, Side View End View, Heater Specifications, Venting Specifications, Length