1.Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep.
2.Fold wall anchor as shown in figure 8 below.
Figure 8.
3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.
4.For thin walls (1/2” or less) insert red key into wall anchor.
5.Place mounting bracket onto wall. Line up holes on each end of bracket with wall anchors.
6.Insert mounting screws through bracket and into wall anchors.
7.Tighten screws until mounting bracket is firmly fastened to wall.
Placing Heater on Mounting Bracket
1.Locate two horizontal slots on back pane of heater (see figure 9).
2.Place heater onto mounting bracket. Slide hori- zontal slots onto
Horizontal Slots
Mounting Bracket mounted to wall
Figure 9.
Installing Bottom Mounting Screws
1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see figure 10).
Figure 10
2.Mark screws locations on wall.
3.Remove heater from mounting bracket.
4.If installing bottom mounting screw into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching to Wall using Anchor. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64” drill bit.
5.
6.Place spacers between bottom mounting holes and wall anchor or drilled hole.
7.Hold spacer in place with one hand. With the other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.
8.Tighten both screws until heater is firmly se- cured to wall. Do not over tighten.
Note: Do not
FLOOR MOUNTING AWAY FROM WALL:
Figure 11
Installing Support Feet (see figure 11)
1.Lay heater onto table on its back with bottom edge overhanging table edge.
2.Securely attach feet to bottom of heater using 2 –
Note: Feet should have long end going out the front of heater, and the edge coinciding with side of heater. If feet overhang side of the heater, switch leg location.
3.Place heater on
Note: Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection.
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes.
Unvented Natural Gas Fired Room Heater | 7 | Installation Instructions and Owner’s Manual |