Page | 15
FLOORPROTECTION
• Thiswoodstoverequiresanon‐combustiblefloorprotectorifthestoveistobeinstalledona
combustiblefloor.Ifthefloorthestoveistobeinstalledonisalreadynon‐combustible(i.e.a
concretefloorinabasement),nofloorprotectionisneeded(althoughadecorativefloorprotector
canstillbeusedforaestheticreasons).
• Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduceheating
andcoolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortarandgroutjoints
locatednearthestove.
• ThefloorprotectorshouldbeULapprovedorequivalentandmustbenoncombustiblewithanR
valueof0.5.Sincethemajorityoftheheatfromthisunitisradiant,thefloorprotectornotonly
servestokeepashesandsparksfromlandingoncombustibleflooringneartheunitbutalso
protectsthecombustiblefloorfromtheheatoftheunit.AhearthrugisNOTanapproved
substituteforaproperhearthpad.
• FortheUS:Thefloorprotectormustextendatleast16in.fromthefrontofthefuelopening,8in.
fromthesidesofthedooropeningand8in.fromtherearoftheunit.
• ForCanada:Thefloorprotectormustextendatleast450.0mmfromthefrontofthefuelopening,
200.0mmfromthesidesofthedooropeningand200.0mmfromtherearoftheunit.
• Thenon‐combustiblefloorprotectormustextend2in.(50.8mm.)oneithersideofanyhorizontal
ventingrunsandextenddirectlyunderneathanyverticalventingpipe.
• PleaseseethefollowingpageforinstructionsoncalculatingRvalues,tobecertainthatthe
plannedfloorprotectionisadequateforthisstove.
US:8.0in.
CANADA:200.0mm.
US:8.0in.
CANADA:200.0mm.
US:8.0in.
CANADA:200.0mm.
US:16.0in.
CANADA:450.0mm.
CAUTION