Connecting to the Network
Matrix DFE-Gold Series Modules Hardware Installation Guide 3-15
e. EnsurethatthetwistedpairconnectionmeetsthedBlossandcablespecifications
outlinedintheCablingGuide.Referto“RelatedDocuments”onpagexvifor
informationonobtainingthisdocument.
Ifalinkisnotestablished,contactEnterasysNetworks.Referto“GettingHelp”on
pagexviiifordetails.
4. Repeatsteps1through3above,untilallconnectionshavebeenmade.
Connecting UTP Cables to 4H4283-49 or 4H4203-72
The4H428349 and 4H420372 havefixedRJ21connectors.EachRJ21connectorcan
supportupto12segments.YoucanuseeitherstraightRJ21cableconnectorsorright
angleRJ21connectorswithoptionalRJ21angleadapters.
ToconnectaUTPsegmenttothe4H428349 or 4H420372,proceedasfollows:
1. EnsurethatthedeviceconnectedtotheotherendofthesegmentispoweredON.If
usingRJ21straightconnectors,proceedtostep 2.IfusingRJ21connectorswith
optionalRJ21angleadapters,proceedtostep3 .
2. IfusinganRJ21straightconnector,refertoFigure39andproceedasfollows.Ifusing
RJ21rightanglecableconnectors,proceedtoStep3 onpage316.
a. PlugtheRJ21straightconnectorintotheappropriateRJ21portconnector.
b. TightenthetwoscrewstosecuretheRJ21straightconnectortotheRJ21port
connector.
c. Proceedtostep 4.
Note: The cable pinouts for a 25-pair cable (RJ21) can be found in the Cabling Guide.
Refer to “Related Documents” on pagexvi for details on how to obtain this document.