clear lldp
Enterasys D-Series CLI Reference 5-27
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleconfiguresthemanagementaddress,MEDcapability,andMEDlocation
identificationTLVstobesentinLLDPDUsbyportge.1.1.
D2(rw)->set lldp port tx-tlv mgmt-addr med-cap med-loc ge.1.1
clear lldp
UsethiscommandtoreturnLLDPparameterstotheirdefaultvalues.
Syntax
clear lldp {all | tx-interval | hold-multiplier | trap-interval | med-fast-repeat}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplereturnsthetransmitintervaltothedefaultvalueof30seconds.
D2(rw)->clear lldp tx-interval
clear lldp port status
Usethiscommandtoreturntheportstatustothedefaultvalueofboth(bothtransmittingand
processingreceivedLLDPDUsareenabled).
all ReturnsallLLDPconfigurationparameterstotheirdefaultvalues,
includingportLLDPconfigurationparameters.
txinterval ReturnsthenumberofsecondsbetweentransmissionsofLLDP
frames.tothedefaultof30seconds.
holdmultiplier Returnsthemultipliertoapplytothetransmitintervaltodetermine
thetimetolivevaluetothedefaultvalueof4.
trapinterval ReturnstheminimumtimebetweenLLSPtraptransmissionstothe
defaultvalueof5seconds.
medfastrepeat ReturnsthenumberoffaststartLLDPDUstobesentwhenanLLDP
MEDendpointdeviceisdetectedtothedefaultof3.