KIT COMPONENTS:

Initial Installation

QUALIFIED INSTALLERS ONLY

FIREPLACE HORIZONTAL VENT KIT 50-1235:

Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury.

KIT COMPONENTS:

Qnty

Description

Qnty

Description

 

 

 

 

1

Horizontal direct vent termination cap

4

Wire spacers

 

 

 

 

1

Flue collar adapter

1

4 oz tube Mill-Pac Sealant

 

 

 

 

1

Wall thimble

1

4 oz tube RTV silicone

 

 

 

 

 

1

5’

(190 cm) length of Ø4” (10 cm) double walled flex pipe

12

9/16” tech screws

1

5’

(190 cm) length of Ø65⁄8” (16.8 cm) double walled flex pipe

8

11⁄2” wood screws

 

 

 

 

 

Please ensure that all components are supplied with this kit. If components are missing or have been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing or damaged.

INSTALLATION INSTRUCTIONS:

1.Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements.

2.Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjusted if obstructions are found in the wall.

3.Project a line from the center point of the flue outlet upward and outward to the desired flue outlet location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall. Cut the hole from the interior through the exterior wall surfaces.

4.Frame the hole as shown in Figure 22.

5.Trim the wall thimble to match the wall thickness as necessary. Install the wall thimble and secure it to the inner wall frame using four (4) 11⁄2” wood screws. If a wall is

greater than 8” (203mm) in depth, the clearance above the flex must be 43⁄8” (111mm)

 

 

 

 

 

6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5

 

 

 

 

 

 

 

 

 

 

cm) provided flue collar adaptor. Press the flue collar into the flue outlet of

 

 

 

 

 

the fireplace so that the Mill-Pac seals the flue collar to the flue outlet.

 

 

 

 

 

7. Stretch both the Ø4” (10 cm) flex vent and the Ø65⁄8” (16.25 cm) flex intake

 

 

 

 

 

liner to the length needed to ensure the flex can be easily connected to the

����

 

 

 

 

vent terminal.

 

 

 

 

 

 

 

 

�������

 

 

 

 

8. Slide the Ø65⁄8” (16.25 cm) flex intake liner

 

 

 

 

 

 

over the flex vent. Install four (4) wire

 

 

 

 

 

 

spacers around the flex pipe. Ensure the

 

 

 

 

 

 

wire spacers are positioned at either end of

 

 

 

 

 

 

the pipes, and at each end of any elbows in

 

 

 

 

 

 

 

 

 

 

 

the liners (refer to Figure 16 and 17).

 

 

 

 

 

 

 

 

 

 

 

9. Install the flex pipe

assembly through

 

 

 

 

 

 

the wall thimble, ensure that this portion

 

 

 

 

 

 

 

 

 

 

 

of pipe slides through the outside wall

 

 

 

 

 

 

far enough to connect onto the vent

 

 

 

 

 

 

Figure 16: Wire Spacers.

termination cap.

 

 

 

Figure 17: Wire Spacer in Place.