Enviro Ascot owner manual Initial Installation, Straight Through Wall Installation

Models: Ascot

1 40
Download 40 pages 32.25 Kb
Page 21
Image 21
Figure 26: Straight Through Wall Installation.

Initial Installation

Interior

Exterior

Wall Surface

 

Wall Surface

2.5"

 

(64mm)

Horizontal

 

Inside

Vent Section

 

Finished

 

Collar

 

 

Horizontal

 

Vent

 

Termination

 

Wall

If installed on a

Thimble

 

carpeted surface

 

a hearth is required

Insulation

 

Figure 26: Straight Through Wall Installation.

NOTES:

(1)The horizontal run of vent pipe must be level and should have a 1⁄4” rise for every one foot of run towards the termination. Never allow the vent to run downward. This could cause high temperature and may present the possibility of a fire.

(2)The location of the horizontal vent termination on the exterior wall must not be easily blocked or obstructed. Refer

to INITIAL INSTALLATION - VENT TERMINATION RESTRICTIONS.

(3)When installing a vent pipe in a chase the minimum clearance to combustibles is 2” (51 mm).

NOTE: Vent pipe must not be longer than 18” (457 mm) maximum when installing straight through exterior wall.

Maintain manufacturer’s clearances to combustibles with venting.

Vent may extend between 6” (152 mm) and 18” (457 mm) maximum straight out.

When installing this unit in a corner the maximum distance after 45˚ elbow is 9” (228 mm).

If between 9” (229 mm) and 24” (610 mm), a 14” (356 mm) snorkel must be used.

 

Horizontal

 

Vent

24" (610mm)

Termination

Maximum

 

Horizontal

 

Inside

 

Finished

 

Collar

 

24" (610mm)

Wall

Thimble

Minimum

 

Vertical

 

 

Exterior

 

Wall Surface

 

Insulation

Interior Wall

 

Surface

 

If installed on a

 

carpeted surface

 

a hearth is required

 

Figure 27: Up Then Through Wall Installation.

 

 

21

Page 21
Image 21
Enviro Ascot owner manual Initial Installation, Straight Through Wall Installation