Routine Cleaning and Maintenance

The following list of components should be inspected and maintained routinely to ensure that the appliance is operating at its’ optimum and giving you excellent heat value:

2-3 Days / Weekly

Semi-annually or 2 Tons of Fuel

Burn Pot and Liner

Exhaust Vent

Heat Exchanger Tubes

Air Intake

Ash Pan

Blower Mechanisms

Door Glass

Heat Exchanger Tubes

Inside Firebox

Behind Firebox Liners & Covers

Ash Pan and Door Gaskets

All Hinges

Door Latch

Post Season Clean-up

TOOLS REQUIRED TO CLEAN UNIT:

Torx T-20 Screwdriver, 5/16” wrench or socket, Brush, Soft Cloth, Vacuum with fine filter bag

BURNER POT AND LINER (2-3 days)

Burn Pot Liner

Air Intake Tube

Ignitor Tube

Burn Pot

Figure 5: Bern Burn pot and Liner

Every two to three days (when the unit is cold), remove the burn-pot liner from the stove. Using a metal scraper, remove material that has accumulated or is clogging the liner’s holes. Then dispose of the scraped ashes from the liner and from inside the burn-pot. Place the burn-pot back into the stove, making sure that the pipes are properly inserted into the burn pot. Place the liner back into the burn-pot, making sure that the ignitor hole in the liner is aligned with the ignitor tube. Pushing the liner up against the ignitor tube.

If, after long periods of burning, the fire continually builds up and overflows the burn pot or there is a build up of clinkers, this is an indication that the pellet fuel quality is poor, the stove may need cleaning, or the air adjusted. Check the stove for ash build up (clean if required) and adjust the slider / damper to produce the proper clean combustion.

To clean the burn pot swing the door open. Pull the burn pot clean-out lever in and out several times; the lever is located under the door opening (shown in Figure 6). Ensure the lever is pushed in before closing the door.

HEAT EXCHANGER TUBES (2-3 days)

A handle is located in the center of the stove just above the door (shown in Figure 6). This handle is to be pulled up and down a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fly ash that may have collected on the heat exchanger tubes. As different types of pellets produce different amounts of ash, cleaning of the tubes should be done on a regular basis to enable the unit to run efficiently.

ASH PAN AND DOOR GASKETS (weekly)

After extended use the gasketing may come loose. To repair this, glue the gasketing on using high- temperature fiberglass gasket glue available from your local dealer. This is important to maintain an airtight assembly.

DOOR GLASS CLEANING (2-3 days)

Cleaning of the glass must only be done when stove is cold. Open the door by lifting the handle. The glass can be cleaned by wiping down the outside and inside of the glass with a dry soft cloth.

10

Page 10
Image 10
Enviro C-10792, 50-1220 owner manual Routine Cleaning and Maintenance, Tools Required to Clean Unit

50-1220, C-10792 specifications

Enviro C-10792,50-1220 is an innovative solution designed to meet the increasing demands of environmental sustainability while enhancing operational efficiency across various industries. This advanced product has been engineered with a focus on performance, durability, and eco-friendliness, making it ideal for organizations looking to minimize their environmental footprint without compromising on quality.

One of the primary features of Enviro C-10792,50-1220 is its exceptional compatibility with a wide range of materials. The formulation is designed to work seamlessly with various substrates, ensuring a strong bond that enhances the longevity of applications. This characteristic is particularly beneficial in sectors such as construction and manufacturing, where adherence to strict performance standards is essential.

Technology plays a pivotal role in the development of Enviro C-10792,50-1220. The product utilizes cutting-edge nanotechnology to enhance its properties, resulting in increased resistance to environmental stressors such as UV exposure, moisture, and temperature fluctuations. This innovative approach not only improves the product's longevity but also ensures that it maintains its structural integrity over time, reducing the need for frequent maintenance or replacements.

In terms of environmental impact, Enviro C-10792,50-1220 is formulated to be low in volatile organic compounds (VOCs). This characteristic makes it a safer choice for workers and the surrounding environment, aligning with global standards for environmentally friendly materials. By choosing this product, companies can contribute to cleaner air quality and reduced pollution levels, which is increasingly important in today’s regulatory landscape.

Another notable characteristic of Enviro C-10792,50-1220 is its easy application process. The user-friendly formulation allows for quick and efficient installation, reducing labor costs and minimizing downtime. This ease of use does not compromise the performance, ensuring that projects can be completed on time without sacrificing quality.

In summary, Enviro C-10792,50-1220 stands out as a versatile, durable, and eco-friendly solution suitable for various applications. With its advanced technology and robust characteristics, it enables organizations to achieve their sustainability goals while maintaining high performance standards. As industries continue to evolve towards more sustainable practices, Enviro C-10792,50-1220 is poised to play a crucial role in this transformation.