Operating Instructions
SPECIAL NOTES:
Pellet quality is a major factor in how the pellet stove will operate. If the pellets have a high moisture content or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash
CONTROL BOARD FUNCTIONS: |
|
|
|
| |
1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim | |||||
button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the feed | |||||
rate to four (4) seconds ON time per Auger pulse. This is done only on LOW to allow the burning of | |||||
poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On | |||||
time to two (2) second. This setting is for | |||||
1 light is on, this is for a three (3) second on time (standard setting). |
|
| |||
2. AUGER PULSE LIGHT: This light will flash in conjunction with the auger. |
|
| |||
|
| 3. MANUAL AUGER FEED: If the unit runs out of fuel, this | |||
|
| button can be used to “prime the auger system”. This button | |||
|
| will turn off after 60 seconds and then must be released and | |||
| 1 | pressed again. |
|
| |
| 4. SYSTEM LIGHT: Responsible for signaling the state of the | ||||
|
| ||||
|
| control board. When the light is flashing during | |||
|
| stove is in an automatic start mode. When the light is solid, | |||
|
| the Heat Level Setting can be altered. |
|
| |
� | 2 | 5. ON/OFF BUTTON: Used to turn the unit ON and OFF. |
| ||
MANUAL FEED | 6. HEAT OUTPUT INDICATOR: Shows | the present | heat | ||
| |||||
3 | output setting. |
|
| ||
|
|
| |||
| 4 | 7. HEAT LEVEL ADJUSTMENT: When | pressed, the | heat | |
ON/OFF | output setting of the unit will change from low to high. |
| |||
| Notes: |
|
| ||
7 | 5 |
|
| ||
HEAT LEVEL |
| • The convection blower speed will vary automatically with the | |||
|
| feed rate. |
|
| |
|
| • Due to varying fuel qualities this pellet stove may not operate | |||
|
| on lower Heat Level settings. If your unit goes out when on a | |||
|
| low setting move the heat level up to a higher setting. |
|
Figure 2: Circuit Board Control Panel Decal. • The lowest and highest heat levels on this pellet stove are
|
|
|
| used for adjusting and accommodating |
| Auger Trim | Auger Trim | Auger Trim | for different pellet sizes and the varying |
| energy produced by the fuels. The size | |||
|
|
|
| |
|
| 5 |
| of the pellets will change the volume of |
4 | 2 Seconds | 3 Seconds | 4 Seconds | fuel being fed. |
| "ON" |
| ||
| "ON" | "ON" | • The unit should be run at a setting | |
| Factory Setting | |||
|
|
| ||
1 | 1 | 1 |
| where the least amount of cleaning of |
| the burn pot is needed. | |||
|
|
|
|
Figure 3: Auger trim and heat level indicator.
7