HORIZONTAL EXHAUST THROUGH THE WALL

1.Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house framing, plumbing, wiring, etc.

2.Install a non-combustible hearth pad (where necessary).

3.Place the appliance 15” (37.5 cm) away from the wall. If the stove is to be set on a hearth pad, set the unit on it.

4.Locate the center of the exhaust pipe on the stove. Extend that line to the wall. Once you have located the center point on the wall, use a hole saw to cut a 7” (175 mm) diameter hole for a 3” (76 mm) vent pipe or an 8” (200 mm) hole for a 4” (101 mm) vent pipe.

5.Install the wall thimble as per the instructions written on the thimble.

6.Install a length of 3” (76 mm) or 4” (101 mm) vent pipe into the wall thimble. The pipe should install easily into the thimble.

7.Install the fresh air intake (SEE PAGE 23)

8.Connect the exhaust vent pipe to the exhaust pipe on the stove. Seal the connection with high temperature silicone

9.Push the stove straight back, leaving a minimum of 2” (5 cm) clearance from the back of the stove to the wall. Seal the vent pipe to the thimble with high temperature silicone.

10.The pipe must extend at least 12’ (30 cm) away from the building. If necessary, bring another length of pipe (PL type) to the outside of the home to connect to the first section. Do not forget to place high temperature silicone around the pipe that passes through the thimble.

11.Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless steel cap termination manufactured by the vent manufacturer is recommended. However, when the vent terminates several feet above ground level and there are no trees, plants, etc. within several feet, a 45-degree elbow can be used as termination. The elbow must be turned down to prevent rain from entering.

5 5/8”

10 3/16”

715/16”

 

Note: Some horizontal, through the wall installations may require a “T” and 4-5 feet (122 to 152 cm) of vertical pipe outside the building to help the stove draft properly. This may be required if a proper burn cannot be maintained, after the stove has been tested and the airflow set. This is due to backpressure in the exhaust, caused by the airflow around the house.

15 1/8”

19

Page 19
Image 19
Enviro EF-IV I technical manual Horizontal Exhaust Through the Wall

EF-IV I specifications

The Enviro EF-IV I is an innovative next-generation environmental control unit designed to meet the diverse needs of modern aviation. With a strong focus on efficiency, reliability, and sustainability, the EF-IV I has garnered attention for its cutting-edge features and advanced technologies that elevate cabin comfort while reducing the ecological footprint.

One of the most notable features of the Enviro EF-IV I is its hybrid cooling technology. By integrating both conventional and thermal energy systems, the unit can operate with higher efficiency across various conditions. This technology allows for significant energy savings while maintaining optimal temperature control in the cabin, making it an ideal choice for eco-conscious airlines looking to minimize operational costs.

The EF-IV I boasts a sophisticated air filtration system that enhances cabin air quality. Utilizing advanced HEPA filters and multi-layer filtration processes, this unit captures airborne particles and contaminants, ensuring that passengers breathe clean and fresh air during their flights. Its intelligent monitoring system continuously assesses air quality parameters and adjusts filtration performance in real-time, providing a proactive approach to maintaining a healthy cabin environment.

In terms of user interface, the EF-IV I is equipped with an intuitive digital control panel that allows crew members to easily monitor and adjust settings. This interface features an interactive display providing valuable data on system performance, energy consumption, and maintenance schedules, empowering operators with real-time insights that contribute to seamless operations.

The compact design of the EF-IV I facilitates easier installation and integration into existing aircraft systems, making it a flexible choice for both new aircraft and retrofitting older models. Its lightweight materials and streamlined construction not only minimize weight and improve fuel efficiency but also enhance overall durability and reduce maintenance requirements.

Finally, the Enviro EF-IV I is built with sustainability in mind. Its materials and manufacturing processes are compliant with international environmental standards, ensuring that the unit adheres to stringent regulations and contributes positively to the overall environmental impact of aviation.

With its advanced features, sustainability focus, and commitment to enhancing passenger experience, the Enviro EF-IV I represents a significant step forward in environmental control technology for the aviation industry. It is a testament to the ongoing innovation and dedication to creating a more sustainable future in air travel.