8. ROUTINE MAINTENANCE

Periodically check to ensure that the "B-Vent" venting system is clear and that a negative draft is present when the unit is operating.

Periodically check the pilot and burner flames

CLEANING OF GLASS

Do not clean glass when hot

It will be necessary to clean the ceramic glass periodically. During a cold start up condensation will sometimes form on the glass, this is a normal condition with all gas fireplaces and stoves. However, sometimes this condensation can allow dust and lint to cling to the glass surface. Also, sometimes the initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary problem. It is therefore recommended that the glass be cleaned initially after about the first two weeks of use.

After that, depending upon the amount of use, cleaning should be required no more than two or three times per season.

To clean the door, use a mild glass cleaner and a soft cloth. Abrasive cleaners will damage the glass surface.

OPENING THE GLASS DOOR

Turn unit off and wait until the appliance has cooled down.

1.Open the right hand hinged side flap that will expose a door fastener. Using a 1/2" wrench, loosen off the fastener.

2.Due to the shape of the bay window door. You must also open the left-hand side flap before attempting to open the Bay window door.

3.Ensure the door is properly fastened after cleaning before attempting to re-light the appliance.

4.Remove all fingerprints from all gold before lighting this appliance.

TO REPLACE DOOR AND GLASS ASSEMBLY

The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a replacement door assembly including glass must be fitted.

open door fully

Lift door vertically so that the hinge pins lift out of hinge receivers.

Return assembly to dealer.

Your ENVIROGAS Dealer must replace door and glass assembly as a complete unit. No substitute materials are

allowed.

FOR CLEANING THE INSIDE OF THE FIREBOX

Remove the log set carefully from the firebox. Gently remove the embers and place on a piece of paper towel. Until ready to replace.

Vacuum the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner.

After carefully replacing the logs and embers in their correct positions, and the door has been resealed, re- light the pilot, following the instructions on the attached label.

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE

LUBRICATING THE BLOWERS

EVERY 6 MONTHS

1.Turn the unit off and remove the log set.

2.Remove the burner tray assembly by removing the screw on either side of the tray, between the front and rear burners. Lift tray out.

3.Remove the 8 screws that hold the blower mounting plate to the back firewall.

4.Carefully pull the blower assembly into the firebox,

exposing the blower lubricating holes (located on the top of the motor housing on either side of the label). Add 2 drops of SAE 20 oil.

If removal of the blower is necessary, disconnect the 2 black blower leads from the terminal block, located on the floor of the fan compartment. Remove the blower.

5.To re-install, check gasket and reverse steps 1 through 4.

10

Page 10
Image 10
Enviro EG-40 owner manual Routine Maintenance