Maintenance And Service

to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualified service person. The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed.

MAINTAINING FASCIA AND SURROUND FINISHES:

When a plated surround or face is received, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. If your fingers come into contact with the finishes, the oils left as fingerprints on the plating can become permanently etched in the surface. To prevent this, clean the painted surfaced with a damp cloth and clean plated finishes with denatured alcohol after the installation and prior to first firing of the fireplace. If your fingers come into contact with the antique copper finish, the oils left as fingerprints on the copper can cause discoloration, which will eventually turn green in that area. You can clean the patina or discolored areas of the antique copper finish with “OO” 3M green sanding pads. These can be purchased from most hardware stores. On the areas with discoloration, use the sanding pads to sand in the same direction as the brushed finish, then blend the finish by feathering in the surrounding area. This refinishing procedure has been approved by the manufacturer and will not harm the finish. Please note: ANTIQUE COPPER IS THE ONLY FINISH THAT CAN BE SANDED, DO NOT SAND PEWTER, GOLD OR NICKEL FINISHES.

BURNER AND BLOWER REMOVAL:

1.Turn the unit off, remove the glass door (see MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL) and the log set. Caution: Bleed lines before lighting and light pilot with door open.

2.Remove the burner tray top by removing the two (2) T-20 screws located in the center of the burner tray (see Figure 7). Slide tray to the left and lift out.

3.Remove brick panels (see SECONDARY INSTALLATION - BRICK PANELS INSTALLATION).

4.Remove the surround panel by lifting it straight up and then out to free it from the body of the unit.

5.Turn the gas supply off and remove gas connection and disconnect the wiring from the side of the appliance.

6.Remove the three (3) T-20 screws that hold the air deflector in place on the back firewall (see Figure 7)

and undo the remaining screws that hold the burner assembly in the appliance. Carefully remove the

gas tray assembly from the firebox,

Air deflector

ensuring that wires and gas lines are

not damaged.

 

7. Remove the blower and housing from

Gas and electrical

the gas tray assembly by removing

tray complete

 

the fastening screws located on

 

the back of the gas tray assembly.

Burner top

Disconnect the wiring from the fan

temperature sensor and remove.

 

To install; follow steps 1 through 7 in

 

reverse. Perform a gas leak check on all

 

gas line with a soap and water solution

 

or an approved method and check

 

burner and blower assembly for proper

 

operation.

Figure 7: Removing Burner and Gas Tray.

9

Page 9
Image 9
Enviro EG31-118 owner manual Ensuring that wires and gas lines are