Initial Installation
QUALIFIED INSTALLERS ONLY
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
PREPARATION FOR INSTALLATION:
•Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible.
•Before beginning, carefully check the glass door and the log set
•Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building; e.g. cutting a wall or ceiling joist.
•Check stove and flue system clearance requirements.
•Locate the stove where it can be accessed by a gas supply line.
•Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation and comfort.
•As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8 m) of the stove.
•The flow of combustion and ventilation air must not be obstructed.
CLEARANCES TO COMBUSTIBLES:
A) Sidewall to unit | 10 inches | (254 mm) |
B) Backwall to unit | 21⁄2 inches | (64 mm) |
C) Corner to unit | 21⁄2 inches | (64 mm) |
D) Ceiling bottom of unit | 60 inches | (1524 mm) |
E) Floor | 0 inches | (0 mm) |
Note: Must have hearth pad if installed on a carpeted surface.
If this unit is installed in an alcove the alcove must meet these minimum dimensions:
Width | 48 inches | (1219 mm) |
Height | 60 inches | (1524 mm) |
Maximum Depth | 24 inches | (610 mm) |
|
| ���� ���� | �������� ���� |
|
| � | |
���� ���� |
| � | |
|
| ||
� |
| � | |
|
| ||
| ����� | ������������ | |
|
|
Figure 12: Clearances to combustibles.
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.
12