EPSON Stylus Photo 750 Revision A

Adjustment Adjustment by Adjustment Program 89

5.3.8 Counter Value for Ink Absorber
This function is for indicating the protection counter value for the waste
ink absorber and resetting the counter value. This function can be also
performed from the control panel. (See “Special Setting Mode” on
page -22)

5.3.8.1 Protect Counter Value

1. Select “Maintenance” on the main menu and press Return key. The
screen goes to the maintenance menu.
2. Select “Indication of the Counter Value for the Waste Ink Pad”, and
press Return key.
3. The screen goes to “Protect Counter Check/Clear Menu”. Select
“Check the present counter value” and press Return key. Then,
current protector count value appears.
4. If the counter value exceeds the limit, replace the waste ink
pad(absorber) and reset the protect counter.
5. Press ESC key and return to the “Protect Counter Check/Clear
Menu”.

5.3.8.2 Protect Counter Reset

1. Select “Maintenance” on the main menu and press Return key. The
screen goes to “Maintenance Menu”.
2. Select “Indication of the Counter Value for the Waste Ink Pad”, and
press Return key. The screen goes to “Protect Counter Check/Clear
Menu”.
3. Select “Clear the protect counter value” and press Return key.
4. Check if it is necessary to change the pad or not, and select “Yes”
and press Return key.
5. Press ESC key and go back to the Main Menu.
Auto