Table 5-12. Print Quality Anomalies (Continued)Symptom Possible Cause Part Name Check Item Remedy
Blank print
Poor
development
Imaging
cartridge
Check whether the
toner cartridge is
installed properly.
Reinstall the toner
cartridge.
PWB-F board — Replace the PWB-F
board.
Improper
charging PWB-F board — Replace the PWB-F
board.
Poor image
transfer
Image transfer
unit
Check the surface of
the image transfer
unit.
Replace the image
transfer unit.
PWB-F board — Replace the PWB-F
board.
Improper print
density setting —— Adjust the print
density using the
printer settings.
Defective optical
unit Optical unit — Replace the optical
unit.
Black print Improper
charging
Photoconduc-
tor unit —Replace the
photoconductor unit.
PWB-F board — Replace the PWB-F
board.
Poor
development
Toner
cartridge —Replace the toner
cartridge.
PWB-F board Replace the PWB-F
board.
Improper print
density setting —— Adjust the print
density using the
printer settings.
Defective optical
unit Optical unit — Replace the optical
unit.
White/black lines
and bands.
Improper
charging Photoconduc-
tor unit —Replace the imaging
cartridge.
Poor
development
PWB-F board — Replace the PWB-F
board.
Toner
cartridge —Replace the toner
cartridge.
Dirt on the fusing
roller Fusing roller — Clean the fusing roller.
EPL-5500W Service Manual Troubleshooting
Rev. A 5-9