Table 5-12. Print Quality Anomalies (Continued)
Symptom Possible Cause Part Name Check Item Remedy
Toner smudges on
the back side of the
sheet.
Improper
charging PWB-F — Replace the PWB-F
board.
Poor
development PWB-F — Replace the PWB-F
board.
Improper fusing Fusing unit — Replace the fusing
unit.
Offset print
Improper fusing Fusing unit — Replace the fusing
unit.
White spots Poor image
transfer
Image transfer
unit —Replace the image
transfer unit.
PWB-F — Replace the PWB-F
board.
Troubleshooting EPL-5500W Service Manual
5-10 Rev. A