Signal | Return |
|
|
|
pin | pin | Signal | Direction | Description |
|
|
|
|
|
33 | - | GND | - | Same as for pins |
|
|
|
|
|
34 | - | NC | - | Not used |
|
|
|
|
|
35 | - | +5 V | OUT | Pulled up to +5 V through |
|
|
|
| 1 KΩ resistance |
|
|
|
|
|
36 | - | NC | - | Not used |
|
|
|
|
|
Notes:
❑The column heading “Direction” refers to the direction of signal flow as viewed from the printer.
❑“Return pin” denotes the
❑All interface conditions are based on TTL level. Both the rise and fall times of each signal must be less than 0.2 microseconds.
❑Data transfer must be carried out by observing the ACKNLG or BUSY signal. Data transfer to this printer can be carried out only after receipt of the ACKNLG signal or when the level of the BUSY signal is LOW.
Timing chartThe figure below shows the timing chart for the parallel interface.
BUSY
ACKNLG
DATA
STROBE
0.5 μs (Min.)
0 μs (Min.)
5 μs (Typ.)
0 μs (Min.)
Transition time (both the rise and the fall) of every signal must be less than 0.2 μs.