6-8 Peripherals/Option Installation Rev.A
Confidential
The directory where the file is copying to can be specified to the parameter as an option, an d also
can be omitted. If it is omitted, th e file is copied to “C:\TOUCH". It automatically copies the file
and completes the copying of file.
Type the command written below on the prompt to install the driver.
MEDVSTD I10,P2E8,B96[Enter]
Parameter “I10" specifies IRQ 10, “P2E8" specifies I/O address 2E8h, and “B96" specifies Baud
Rate 9600.
Windows 95/98, Windows NT
Follow the steps below.
1. Start C:\BACKUP\VIDEO\W95500.EXE.
2. Welcome Screen is displayed.Welcome. Clock on [Next]button.
3. Software License Agreement Screen is displayed. Click on [Yes]button, only if you agree on
the agreement. Copying of file is executed.
4. The Setup Complete Screen is displayed when the copy is completed. Select "Yes, I want to
restart ....:” , then click on [Finish] button.
5. It reboots the system. Change the settings from the [Control Panel:Display
Properties:Settings Tab] if it’s necessary.
CalibrationThe calibration modifies the touch panel pressed position and the system coordinate to be
matched.
MS-DOS
Follow the steps below for the calibration.
1. Move to the touch panel directory.
2. Type FPCAL[Enter]. Calibration utility starts .
3. Click on the points on the [+] character. The [+] char acter is displayed sequentially in nine
places on the screen. (Top : left/middle/right, Middle : left/middle/right, Low : left/
middle/right)
4. It automatically exits the utility when the procedure is completed.
Windows 95/98, Windows NT
Environmental Setting Tool Setup
Execute the calibration from the environmental setting tool in Windows95/98 andWindowsNT.
Start the Touch Panel Environmental Setting from the execution file (EpsTpCal.exe).
Click on “Start” from the Windows. Select “programs”-”EPSON Touch Panel”-”Touch Panel
Configuration Tool” and run the program.