Rev.A BIOS Setup 3-23
Developer's Guide SR-600
Confidential
Changing/Deleting the Password for the Drawer Kick Out Test
Follow the procedures below to change or delete th e password for the drawer kick out test.
1. Select “Drawer Password” from the pull down Setup menu. You are asked to enter the
password.
2. Enter the current password and press Enter key.
3. Message “New” appears.
4. Press Enter key only to delete the password. Enter new password and press Enter key to
set a new password.
5. Message “Re-Enter” appears. Enter the password again and press the Enter key to
change or delete the password.
Setting Drawer ON time
Drawer ON time option sets the length of time for the voltage signal supplied to the cash drawer
solenoid to open.
3-3 Enter Drawer On Time screen
Select Drawer ON time option from the Setup pull down menu to set the time. The dialog box
appears. Set the length of the voltage signal required by the cash drawer in ms unit. The On
time can be set at any value within a range of 0 to 5 00 ms. The setting is rounded to the
minimum units that can be set by the TM that you are connected to. For the TM-930, the
minimum units are 10 ms, and for other TMs, the minimum units are 2 ms.
Please refer to the cash drawer’s manual for the appropriate value to enter.