X K 3 1 9 0 - A 1+P

step

Operation

Display

Explanation

8

 

[ A LoAd1]

Loading weight 5% Max.

 

press [ 1 ] [ 5 ]

[ d

1500 ]

Example: 1500

 

[ 0 ] [0 ]

 

 

After stable light is on, press [ Enter ]

 

press [ Enter ]

 

 

key.

9

press [ Enter ]

[ noLoAd ]

Confirming zero position again.

10

 

[ ALoAd2 ]

Reloading weight on scale 50% Max.

 

 

 

 

It is better that this loading weight is

 

press [2] [0]

[ 20000 ]

near the F.S. Example: 20000

 

[0][0] [0]

 

 

After stable light is on, press [ Enter ]

 

press [ Enter ]

 

 

key.

11

press [ Enter ]

[H xxxxxx ]

H. L. td indicating three calibrating

 

press [ Enter ]

[L

yyyyy ]

coefficients . Recording them for spare

 

press [ Enter ]

[td

zzzz ]

use.

 

 

 

 

12

 

[ Adr ** ]

communication address (01-26)

 

press [ 1 ]

[ Adr 01 ]

Example: 1

 

press [ Enter ]

 

 

 

13

 

[ bt

* ]

Serial communication baud rate ( 0-4).

 

 

 

 

It respectively represents baud rate: 600,

 

 

 

 

1200, 2400, 4800, 9600.

 

press [ 1 ]

[ bt

1 ]

Example: 1 (1200)

 

press [ Enter ]

 

 

 

14

 

[ tF

* ]

Serial communication Mode:

 

press [ 0 ]

[ tF

0 ]

0- Continuous transmitting mode,

 

press [ Enter ]

 

 

no receiving.

 

 

 

 

1- Command response mode,

 

 

 

 

Example: 0

15

 

Weighing

Calibration End.

 

 

mode

 

Note: At step 6, 7, 8, 9, if press [ Weighing ] key, you can enter next step.

H. L. td indicating three calibrating coefficients .Recording them for spare use.

CAUTION!

When calibration is over, the calibration jumper must be pulled