VII Trouble Shooting

Trouble-shooting overview

Number

Trouble

 

 

Reason

 

 

 

Trouble shooting

 

 

1

Press

<<Power

1.

No

voltage

in instrument

1.

Check

and

solve

the

 

on/Reset”,

the

 

battery

 

 

 

power problem

 

 

 

annunciator

is

2.

The power switch in the back

2.

Turn on the switch.

 

 

not light and no

 

of instrument is not on.

 

 

 

 

 

 

figure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

displayed

 

 

 

 

 

 

 

 

 

 

 

2

No annunciator

1.

The signal is not connected

1.

connected signal cable;

 

 

twinkles

 

 

 

during cable operation.

2.

Install the antenna;

 

 

 

 

 

 

2.

No

antenna installed

during

3.

Install new battery with full

 

 

 

 

 

 

wireless operation.

 

 

power

 

 

 

 

 

 

 

 

3.

No

scale

body

battery

 

 

 

 

 

 

 

 

 

 

 

installed or low voltage

 

 

 

 

 

3

Instrument

 

1.

The weight of the goods

1.

Reset

weight

limit

or

 

alarm,

 

 

 

 

exceed the weight limit or

 

decrease

the

weight

of

 

No

 

weight

 

F.S+9e

 

 

 

goods;

 

 

 

 

value displayed

2.

The battery voltage of scale

2.

Install new battery with full

 

 

 

 

 

 

body is too low

 

 

power

 

 

 

4

The

 

printed

Ink ribbon is used up

 

Replace it with new ink ribbon

 

figure

 

is

too

 

 

 

 

 

 

 

 

 

 

 

vague

 

 

 

 

 

 

 

 

 

 

 

 

 

5

No

 

figure

The ink ribbon is out of slot

Reinstall the ink ribbon

 

 

printed out

 

 

 

 

 

 

 

 

 

 

 

6

Paper

moving

Too much dust on printer head

Clean the printer head and add

 

problem

 

or

 

 

 

 

 

some oil

 

 

 

 

stopped

 

 

 

 

 

 

 

 

 

 

 

 

7

Too

 

weak

1.

No battery installed in scale

1.

Install

battery

 

 

 

signal

 

 

or

 

body

 

 

2.

Install antenna

 

 

 

irregular

 

2.

No antenna installed

 

3.

Replaced right antenna

 

 

twinkle

 

of

3.

Inappropriate

 

antenna

4.

Shorten

the

distance

 

annunciator

 

 

specification

 

 

 

between

the indicator

and

 

 

 

 

 

4.

Wireless

communicating

 

the scale body

 

 

 

 

 

 

 

 

distance is too long

 

 

 

 

 

 

Appendix

Specification of optional, wearable, quick-wear and expendable parts

Number

Name

Model

Code

Remarks

1

Storage battery

1.6Ah/12V NiH battery

 

Indicator battery

2

Storage battery

2.2Ah/12V NiCd battery

 

Scale-body battery