Equator CM 3000 A. Sliding Tabletops, B. Doors, C. Top Element Assembly, Disassembly And Assembly

Models: CM 3000

1 9
Download 9 pages 60.36 Kb
Page 5
Image 5

DISASSEMBLY AND ASSEMBLY

ENSURE APPLIANCE IS DISCONNECTED FROM THE ELECTRICITY SUPPLY BEFORE DISASSEMBLING.

NOTE ALL CONNECTION DETAILS AND ROUTING OF LEADS BEFORE DISASSEMBLING.

Numbers appearing in the text rater to illustrations and parts list numbers.

A. SLIDING TABLETOPS

Slide both tabletops open. Remove cover caps 130 end the two screws securing handle 105. Withdraw the handle from the tabletop assembly.

Slide the tabletop required inwards, past its closed position, until the two plastic sliding blocks 106 on the cabinet channels are exposed. Withdraw the sliding blocks from the cabinet channels, and than slide the tabletop assembly out clear of the channels.

B. DOORS

1.Remove both sliding tabletops completely (see A.1.) and magnetic door catches 111 (push-fit).

2.Drill out the rivet at each end of the front slide channel using a 3mm bit. Use extreme care when drifting. Withdraw leg top caps 108, then remove front top panel 109 to release top door pivots 128. Lift doors 123 and 125 clear of the cabinet.

C. TOP ELEMENT ASSEMBLY

1.From Inside of cabinet, squeeze locking barbs and release mains lead bush 121 retainer from rear panel. Remove rear cover strip 510, secured by a single screw, to the extant of the mains lead wires. Disconnect the top element leads from terminal block 120.

NOTE: Terminal block 120 Includes push-in locking terminals for internal wiring. Leads inserted in the front-most terminals may only be released by inserting & small screwdriver or similar in the slots provided in the front of the terminal block. Rear-most leads may release with a sharp pull. If leads cannot be released, or are not gripped on insertion, item 120 must be replaced.

2.Open the sliding tabletops and remove glass dishes and lids 101 and holders 103.

3.Remove the sliding tabletops as in A. 1. Then slide each tabletop in turn inwards past its closed position to gain access to the four screws securing top element assembly 107.

4.Use a powerful magnet or suitable tool to lift the element assembly out clear of the cabinet, feeding the element wires through grommet 110 in the cabinet.

5.Refit in reverse order, taking care that the rear cover strip fixing screw is clear of cables when fixing.

2

Page 5
Image 5
Equator CM 3000 service manual A. Sliding Tabletops, B. Doors, C. Top Element Assembly, Disassembly And Assembly