D.MIDDLE AND BOTTOM ELEMENT ASSEMBLY / NEON

D.MIDDLE AND BOTTOM ELEMENT ASSEMBLY / NEON

1.Remove rear cover strip 510 as shown in C.1. And disconnect the middle shelf element leads 113 from terminal block 120 (See note in C. 1.)

2.Remove the two screws securing the element assembly through the rear panel of the cabinet, and two screws from under the front edge of the shelf (bottom element front screws are under the front of the cabinet,behifld the bottom. rail) — see fig.1.

3.Lift the element assembly out clear of the cabinet, feeding the element wires. through grommet 110 in the cabinet.

4.Neon 11 8 is a push fit assembly which is located by two barbs that spring open behind element panel trim 5.1.5. It can only be removed from the front. Pushing from behind the neon assembly (inside the front shelf rail) using a suitable tool can assist removal.

To re-fit, thread the neon leads through the hole in the element panel trim 51 5, push-fit neon into hole and route with element leads to terminal block.

5.Re-fit in reverse order, taking care that the rear cover strip fixing screw is clear of cables when fixing.

Fig. - HL6232E/F Element Assembly Fixing Points

E. MAINS LEAD

1. Remove rear cover strip 510 as in C.l.

2.Disconnect LIVE and NEUTRAL mains lead wires from terminal block 1 20: release the earth lead from the cabinet earth stud.

3.To remove mains lead bush 121, rotate the retainer arm through 90º, then use pliers to squeeze the mains lead locking tab and push the bush, complete with mains lead, out of the cover strip.

4.Refit in reverse order, ensuring correct wire colour connections and that a sound earth connection is made.