FRONT END ALIGNMENT

EQUIPMENT REQUIRED

1.Test Set Models 4EX3A11, 4EX8K12, or 20,000 ohms-per-Volt multimeter with a 1 Volt scale.

2.A 406-512 MHz signal source.

PRELIMINARY CHECKS AND ADJUSTMENTS

1.Connect black plug from Test Set to Receiver Centralized Metering Jack J601, and red plug to system board metering jack J905. Set meter sensitivity switch to the TEST 1 position (or 1-Volt position on 4EX8K12).

2.For multi-frequency receivers with a frequency spacing up to 0.800 MHz for frequency range of 406-470 MHz, 0.900 MHz for frequency range of 470-494 MHz or 0.750 MHz for frequency range of 494-512 MHz, align the receiver on the channel nearest center frequency.

For multi-frequency receivers with a frequency spacing exceeding the above but no greater than 1.60 MHz for frequency range of 406-470 MHz, 1.80 MHz for frequency range of 470-494 MHz, or 1.50 MHz for frequency range of 494-512 MHz, align the receiver using a center frequency tune-up ICOM. These limits can be extended to 2.00 MHz, 2.30 MHz and 2.00 MHz respectively, with 3 dB degradation in standard receiver specifications.

3.With Test Set in Position J, check for regulated +10 Volts. If using multimeter, measure between J905-3 (+) and J905-9 (-).

4.If using multimeter, connect the negative lead to J601-9 (A-).

5.Disable Channel Guard.

ALIGNMENT PROCEDURE

 

METERING POSITION

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST

INTERNAL

MULTIMETER

TUNING

METER

 

 

STEP

SET

METERING

-AT J601-9

CONTROL

READING

 

PROCEDURE

 

 

 

 

 

 

 

 

 

 

OSCILLATOR/MULTIPLIER

 

 

 

 

 

 

 

 

 

 

 

1.

C

3

Pin 3

C406

Maximum

 

Tune C406 for maximum meter reading.

 

(MULT-1)

(MULT-1)

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

 

 

 

C411, C416,

See

 

Preset C411 and C416 to a position similar to C406. Next, preset

 

 

 

 

C306, C307 and

Procedure

 

C306, C307 and C308 fully counterclockwise. (Minimum capacity.)

 

 

 

 

C308

 

 

 

 

 

 

 

 

 

 

 

3.

D

4

Pin 4

C411, C416,

See

 

Tune C411 and C416 for maximum meter reading. Next, retune

 

(MULT-2)

(MULT-2)

 

C406

Procedure

 

C406, C411 and C416 for maximum meter reading. Then carefully

 

 

 

 

 

 

 

tune C306 for a change in meter reading (peak or dip).

 

 

 

 

 

 

 

 

4.

F

5

Pin 7

C306, C307 &

See

 

Carefully tune C307 and C306 for maximum meter reading. Repeat

 

(MULT-3)

(MULT-3)

 

C308

Procedure

 

the procedure. Next, carefully tune C308 for minimum meter

 

 

 

 

 

 

 

reading, and retune C306 for maximum meter reading. Do NOT

 

 

 

 

 

 

 

readjust C307 and C308.

 

 

 

 

 

 

 

 

 

 

 

 

RF SELECTIVITY

 

NOTE: IF AMP meter range is 0-700 mVdc with a high impedance DC voltmeter.

 

 

 

 

 

 

 

 

5.

B

2

Pin 1

C301 thru C305,

Maximum

 

Apply an on-frequency signal to antenna jack, keeping the signal

 

 

(IF AMP)

 

A303-C2, (and

 

 

below saturation. Then tune C301 through C305 and A303-C2 for

 

 

 

 

L2301 if present)

 

 

maximum meter reading. In receivers with the UHS preamplifier,

 

 

 

 

 

 

 

also tune L2301 for maximum meter reading.

 

 

 

 

 

 

 

 

6.

B

2

Pin 1

C301 thru C305,

Maximum

 

Apply an on-frequency signal to the antenna jack and slightly tune

 

 

(IF AMP)

 

A303-C2, C306,

 

 

C301 through C305, A303-C2, (L2301 if present) for best quieting

 

 

 

 

C307 and C308

 

 

sensitivity. C306, C307 and C308 also may be tuned slightly (not to

 

 

 

 

(L2301 if present)

 

 

exceed 1/4 turn).

 

 

 

 

 

 

 

 

406-512 MHz MASTR II RECEIVER

Figure 5 - Test Points And Alignment Controls

Figure 6 - Test Setup For 20 Hz Double-Trace Sweep Alignment

4