FRONT END ALIGNMENT
EQUIPMENT REQUIRED
1.Test Set Models 4EX3A11, 4EX8K12, or 20,000
2.A
PRELIMINARY CHECKS AND ADJUSTMENTS
1.Connect black plug from Test Set to Receiver Centralized Metering Jack J601, and red plug to system board metering jack J905. Set meter sensitivity switch to the TEST 1 position (or
2.For
For
3.With Test Set in Position J, check for regulated +10 Volts. If using multimeter, measure between
4.If using multimeter, connect the negative lead to
5.Disable Channel Guard.
ALIGNMENT PROCEDURE
| METERING POSITION |
|
|
|
| ||
|
|
|
|
|
|
|
|
| TEST | INTERNAL | MULTIMETER | TUNING | METER |
|
|
STEP | SET | METERING | CONTROL | READING |
| PROCEDURE | |
|
|
|
|
|
|
|
|
|
| OSCILLATOR/MULTIPLIER |
|
|
|
| |
|
|
|
|
|
|
| |
1. | C | 3 | Pin 3 | C406 | Maximum |
| Tune C406 for maximum meter reading. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
2. |
|
|
| C411, C416, | See |
| Preset C411 and C416 to a position similar to C406. Next, preset |
|
|
|
| C306, C307 and | Procedure |
| C306, C307 and C308 fully counterclockwise. (Minimum capacity.) |
|
|
|
| C308 |
|
|
|
|
|
|
|
|
|
|
|
3. | D | 4 | Pin 4 | C411, C416, | See |
| Tune C411 and C416 for maximum meter reading. Next, retune |
|
| C406 | Procedure |
| C406, C411 and C416 for maximum meter reading. Then carefully | ||
|
|
|
|
|
|
| tune C306 for a change in meter reading (peak or dip). |
|
|
|
|
|
|
|
|
4. | F | 5 | Pin 7 | C306, C307 & | See |
| Carefully tune C307 and C306 for maximum meter reading. Repeat |
|
| C308 | Procedure |
| the procedure. Next, carefully tune C308 for minimum meter | ||
|
|
|
|
|
|
| reading, and retune C306 for maximum meter reading. Do NOT |
|
|
|
|
|
|
| readjust C307 and C308. |
|
|
|
|
|
|
|
|
|
|
|
| RF SELECTIVITY |
| ||
NOTE: IF AMP meter range is |
| ||||||
|
|
|
|
|
|
| |
5. | B | 2 | Pin 1 | C301 thru C305, | Maximum |
| Apply an |
|
| (IF AMP) |
|
|
|
| below saturation. Then tune C301 through C305 and |
|
|
|
| L2301 if present) |
|
| maximum meter reading. In receivers with the UHS preamplifier, |
|
|
|
|
|
|
| also tune L2301 for maximum meter reading. |
|
|
|
|
|
|
|
|
6. | B | 2 | Pin 1 | C301 thru C305, | Maximum |
| Apply an |
|
| (IF AMP) |
|
|
| C301 through C305, | |
|
|
|
| C307 and C308 |
|
| sensitivity. C306, C307 and C308 also may be tuned slightly (not to |
|
|
|
| (L2301 if present) |
|
| exceed 1/4 turn). |
|
|
|
|
|
|
|
|
Figure 5 - Test Points And Alignment Controls
Figure 6 - Test Setup For 20 Hz Double-Trace Sweep Alignment
4