EVAPORATIVE COOLER

Before Unpack your cooler and install the casters. Slip the Operation stems of the casters into the holes provided in the bot-

tom of the front and back grille.

EVAPORATIVE COOLER

OPERATION

CAUTION: To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device.

Select the area you wish to cool. Evaporative coolers work best near a partially opened door or window to draw in fresh air. An equal amount of air should be discharged out of the room to dispel heat and humidity.

Fill Reservoir Fill the reservoir from the back. The reservoir holds 5 1/2 gallons of water. DO NOT OVER FILL. Water will leak out and could cause water damage to the sur- rounding area. If the reservoir runs dry, it will not harm the pump. When transporting the unit to a different location, be very careful not to spill the water. It is best to re-locate the cooler, and then add water.

Float Included is a float for continuous fill. To attach the Installation float, remove the back grille. Remove the nuts from

the float and insert the float into the water shield and then through the hole in the housing. Secure the float with the nut that was removed. You may connect ei- ther a 1/4 inch hose or a garden hose using the garden hose adapter. Adjust the float so that the water level is about an inch below the top of the reservoir. Reinstall the back grille.

Operation Plug the electrical cord into a 115-120 volt grounded outlet. You may operate your cooler on one of three speeds: low, medium or high. Turn the switch knob clockwise to activate the pump and fan. This will cool the air. Turn the switch counterclockwise to operate the cooler as a fan only (pump will be off).

MAINTENANCE

CAUTION: To reduce the risk of fire, always unplug the cooler before attempting service of any kind.

Motor No oil or lubrication is necessary. The motor is perma- nently lubricated at the factory.

Pump No oil or lubrication is necessary. Clean any debris from under the pump in the inlet area.

Filter Remove the filter from the rear grille and rinse with water. Be careful not to damage the filter! The filter should be replaced every two years or if it becomes clogged.

Water Tank Drain and clean the water tank. To drain, remove the back grille and disconnect the clear hose from the black tube. Turn unit on cool and pump out most of the water. Wipe dry and clean with a towel. Before reattaching the back grille, reconnect the clear hose to the black water tube.

TROUBLE SHOOTING

CAUTION: Always unplug the cooler before attempt- ing service of any kind.

PROBLEM: POSSIBLE CAUSE/REMEDY:

Cooler Does

Not Pump 1. The pump hose may have worked loose. Check the Water connection at the pump and at the water tube located

in the back grille assembly. Reconnect pump hose if necessary.

2.The water tube may be blocked. Remove the tube and clean it out. Make sure water holes are clear.

3.The pump or switch may be defective. Replace pump or switch, if necessary.

PROBLEM: POSSIBLE CAUSE/REMEDY:

Fan Does Not

Operate 1. Verify there is 115-volt power at the electrical outlet. Check the fuse or breaker.

1.The fan switch or motor may be defective. Replace if necessary.

LIMITED WARRANTY

This warranty is extended to the original purchaser only. It does not cover damages incurred during shipping or through accident, neglect, or abuse by the owner. Essick Air Products/Champion Cooler does not authorize any person or representative to assume any other or different liability in connection with this cooler.

Terms And All original parts provided by Essick Air Products/ Conditions Champion Cooler are warranted against defects in Of Warranty material or factory workmanship for one year.

Exclusions Essick Air Products/Champion Cooler is not respon- From sible for incidental or consequential damage resulting

Warranty from any malfunction.

Essick Air Products/Champion Cooler is not respon- sible for any damage occurring from the use of water softeners, chemicals, de-scale material, or if a higher horsepower motor is used in the unit other than what Essick Air Products recommends.

Essick Air Products/Champion Cooler is not respon- sible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.

How To Contact the Dealer where you purchased the evapora- Obtain tive cooler. If for any reason you are not satisfied with Service the response from the Dealer, contact the Customer

Under This Service Department: Essick Air Products, 5800 Warranty Murray Street, Little Rock, Arkansas 72209 or call 800-

643-8341.

Register Register your product online at: