Slave Board Power—On the slave board it is used as communication with the master
board and powering from the master board. Connect the slave board to the master
board using 16 gauge low voltage wire. This wire must be run across the drive-
way and can be up to 100 feet in length. Terminal 6 MUST connect with the
RIGHT side of J2 on the Slave board, Terminal 15 MUST connect with the
LEFT side of J2 on the Slave board.
J3 - Actuator Connections—This terminal is used to connect the operator arm to the
control board both on the master and slave side. IMPORTANT: Follow the above
chart for wire colors. DO NOT EXTEND OR SHORTEN THE OPERATOR
ARM WIRES.

*!

Caution! Do not reverse polarity of the wires
connecting the Master and Slave board. This
will cause permanent damage to both boards
and void your warrantee. Caution!