OWNER’S MANUAL

PS220

SEQUENCING, 2-CHANNEL

REMOTE-CONTROL FLUSH-MOUNT WALL OUTLET

 

PS220

CH 1

TWO CHANNEL

SEQUENCER

 

ETA SYSTEMS

120 VAC

 

A Creative Light And Sound Company

50/60 HZ

 

 

20 AMPS

 

RESET

TOTAL

PROTECTION ON

POWER

SEQUENCING

Air Vents

LED Indicators

PS220 SPECIAL FEATURES:

• Power 120 VAC 50/60Hz, 20 amps total current available,

and 2400 watts total power.

• Sequences 2 outlets - CH 1 and CH 2

• Programmable delay between CH 1 and CH 2 turn off of

1, 5, 10 and 30 seconds

• Remotely turn “ON” or “OFF” the outlets. A remote LED

indicator can be used to show the PS220 activity

• Daisy chain capabilities using a communications port

• Manual reset of the microprocessor

CH 2

CH 1

CH 2

PS220: 3-gang outlet box, 67.3 cu.in. New construction outlet box

Fan

• Spike and surge protection on all three legs of incoming

120V 50/60Hz, single-phase electrical power

• Surge protection is active when the green

(PROTECTION ON) LED is lit.

• Certified to UL1472 and CSA C22.2 No.184.1 standards

SEQUENCING: When activated, the PS220 CH1 outlet turns “ON”, then CH2 outlet turns “ON”. When deactivated the PS220 CH2 turns “OFF”, then CH1 turns “OFF.”

DELAY: A 1, 5, 10 or 30 second time-delay is available between CH1 and CH 2, when turning “ON” or “OFF.” To adjust time delays, place the jumper on J100 to the appropriate location. See diagram below.

RESET: Use the push button switch for resetting the unit’s microprocessor. The Green “POWER ON” LED goes off for 1 second during a manual rest. Use the recommended screwdriver to depress the reset button.

UNIT OPERATION: A Green “POWER ON” LED will indicate when power is present to the unit. (The Green “POWER ON” LED will go off for 1 second during power up, to indicate the microprocessor is ready.) Green “POWER ON” LED will flash while the unit is sequencing on or off, or when another sequencer that is daisy chained in line is sequencing on or off. The two Red CH 1 and CH 2 LED indicators will light when CH1 or CH2 of the receptacle is turned on.

DAISY CHAIN: The PS220 is daisy chained to any other PS220 or 4-channel ETA sequencing unit.

Master Unit: connection to the outputs only (terminals 6 & 7). This output connection is then connected to an input of another ETA sequencing unit.

Slave Unit: connection to the inputs only (terminals 4 & 5). This input connection comes from the output of another ETA sequencing unit.

In-line Unit: this unit has connections to both input and output.

Note: the above-mentioned input and output connections can be connected without regard to polarity.

PS220

SEQUENCER BASE RELAY INSTALLATION OPTION

REMOTE

WALL

PLATE

2 or 3

WIRES

L.E.D. AND

SWITCH

 

PS220

 

 

2 OR 4 CHANNEL

 

2 CH SEQ

 

 

SEQUENCER

 

PS220

2 WIRES

PS220

CH 1

TWO CHANNEL

ETA SYSTEMS

SEQUENCER

 

 

 

120 VAC

 

 

 

PD11SP

50/60 HZ

 

 

 

TOTAL

PROTECTION ON

 

 

20 AMPS

 

RESET

 

 

 

POWER

 

 

PD420VS

 

SEQUENCING

OUT

IN

 

CH 2

CH 2

CH 1

 

 

 

*NOTE: Internal terminal block for hook-up of 3-wire remote and comunications, linking ports

 

2 OR 4 CHANNEL

 

SEQUENCER

2 WIRES

 

PS220

 

PD11SP

 

OUT IN

PD420VS

 

 

TERMINAL BLOCK

CONNECTION

1.Switch (+)

2.Switch & LED (-) Common

3.LED (+) Indicator

4.Input

5.Input

6.Output

7.Output

 

 

J100

 

10 SEC

 

30 SEC

 

 

 

5 SEC

 

 

1 SEC

 

 

 

 

 

1 2 3 4 5 6 7

This is the PC board located inside insulating barrier

1PCB-086

You can change the delay by moving the jumper at J100.

Using the recommended wire, connect to the terminal block using one of the following two options. Recommended Wire: Size 24-22 GA

Max. Wire Length 1000 FT. Screw Torque: .5-.6 Nm Screwdriver: Flatblade .6 x 3.5 x 100mm