Eureka 4390 Series, 4490 Series, 4380 Series HOW TO MAINTAIN continued, Problem, Cause, Solution

Models: 4390 Series 4480 Series 4490 Series 4380 Series

1 11
Download 11 pages 5.86 Kb
Page 11
Image 11
HOW TO MAINTAIN (continued)

HOW TO MAINTAIN (continued)

How To Change Light Bulb (only for models with a headlight)

NOTE: Turn off the power switch and disconnect the electrical cord before changing light bulb.

1.Lower handle. Remove two screws from lens cover.

2.Pull lens cover from cleaner.

3.Pull light bulb and socket toward front.

4. Push light bulb into socket; turn to release.

5.Place new light bulb into socket; turn to secure.

6.Push light bulb and socket back so bulb will not touch lens cover.

7.Replace lens cover.

8.Secure with two screws.

Use 15 watt replacement light bulb, part number 48815.

Problem Solving NOTE: Turn off the switch and unplug electrical cord before servicing.

 

 

 

PROBLEM

 

CAUSE

 

SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor will not start

 

Electric Plug

 

Push plug securely into outlet.

 

 

 

 

 

 

 

 

 

 

 

 

Try another outlet.

 

 

 

 

 

 

 

 

 

 

 

 

Check circuit breaker.

 

 

 

 

 

Motor suddenly

 

Thermal Cut Off

 

Refer to page 3 & 5.

 

 

 

 

 

stops

 

 

 

 

 

 

 

 

 

Does not clean the

 

Filters

 

Clean or replace the filter(s). Hint: If picking up fine dust, the

 

 

 

 

 

carpet or floor.

 

 

 

filter may not look dirty but a fine substance tends to reduce

 

 

 

 

 

 

 

 

 

 

 

 

suction when it blocks the airflow through the filter(s).

 

 

 

 

 

 

 

 

 

 

Cyclonic Cassette

 

Be sure hose adapter inserts into cyclonic cassette.

 

 

 

 

 

 

 

 

 

 

 

 

Be sure the cyclonic cassette is properly seated into the cassette

 

 

 

 

 

 

 

body. See page 4.

 

 

 

 

 

 

 

 

 

 

 

 

Empty cyclonic cassette. Note: There are two chambers in the

 

 

 

 

 

 

 

 

 

 

 

 

cyclonic cassette. The chamber with the screen will fill much

 

 

 

 

 

 

 

 

 

 

 

 

faster than the chamber with the cone. This is normal, when the

 

 

 

 

 

 

 

chamber with the screen is full, empty cyclonic cassette, do not

 

 

 

 

 

 

 

wait till the chamber with the cone is full. See page 7.

 

 

 

 

 

 

 

 

 

 

Belt

 

Replace a cut, loose or out of shape belt.

 

 

 

 

 

 

 

 

 

 

Belt Cap

 

Snap the belt cap inside the hood if it comes loose.

 

 

 

 

 

 

 

 

 

 

Brush Roll

 

Clean hair and thread from bristles and end cap area.

 

 

 

 

 

 

 

 

 

 

 

 

Replace brush roll if bristles are worn.

 

 

 

 

 

 

 

 

 

 

Hose

 

Remove any clogs from the hose that restrict the airflow. Check

 

 

 

 

 

 

 

short hose in the base and long hose. Refer to page 9.

 

 

 

 

 

No suction at the

 

Hose Adapter

 

Hose adapter has to seat inside the cyclonic cassette. Hint: Put

 

 

end of the hose.

 

 

 

the hose in place before attaching the handle. The handle

 

 

 

 

 

 

 

 

 

 

 

 

secures the hose.

 

 

 

 

 

 

 

 

 

 

Filter(s)

 

Clean or replace the filter(s). Hint: If picking up fine dust, the

 

 

 

 

 

 

 

 

 

 

 

 

filter may not look dirty but a fine substance tends to reduce

 

 

 

 

 

 

 

 

 

 

 

 

suction when it blocks the airflow through the filter(s).

 

 

 

 

 

 

 

 

 

 

Hose

 

Remove any clogs from the hose that restrict the airflow. Check

 

 

 

 

 

 

 

 

short hose in the base and long hose. Refer to page 9.

 

 

 

 

 

 

Headlight not

 

Light Bulb

 

Replace light bulb.

 

 

 

 

 

working.

 

 

 

 

 

 

 

 

 

 

Noise from the

 

Brush Roll

 

Remove hood and clean debris or items from the brush roll area.

 

brush roll area.

 

Belt

 

Replace a cut, loose or out of shape belt.

 

 

 

 

 

Cleaner is hard to

 

Cleaner Height Setting

 

Put handle in operating position. Tilt the cleaner back to raise the

push.

 

 

 

front wheels off the floor. Then turn the knob to a higher setting.

 

 

 

 

 

Belt

 

Replace a cut, loose or out of shape belt.

 

 

 

 

 

 

Cleaning height

 

Cleaner Height Setting

 

Hint: Put handle in operating position. Tilt the cleaner back to

 

 

 

 

 

knob will not turn.

 

 

 

raise the front wheels off the floor. Then turn the knob.

 

 

 

 

 

 

Missing parts.

 

 

 

Call 1-800-438-7352 between 8:00 a.m. and 4:45 p.m., central

 

 

 

 

 

 

 

 

 

 

 

 

standard time, Monday through Friday. Know the model and

 

 

 

 

 

 

 

 

 

 

 

 

serial numbers when you call.

 

 

 

 

 

 

Questions?

 

 

 

Call 1-800-282-2886 8 a.m. to 7:30p.m., (CST), Monday -

 

 

 

 

 

 

 

 

 

 

 

 

Friday and 10 a.m. to 6:30 p.m. (CST) Saturday. Know the

11

 

 

 

 

 

 

 

model and serial numbers when you call.

 

 

 

 

 

 

 

Page 11
Image 11
Eureka 4390 Series HOW TO MAINTAIN continued, Problem, Cause, Solution, Use 15 watt replacement light bulb, part number