Euro-Pro EP908H Operating Instructions, Attaching the Accessories to the Flexible Steam Hose

Models: EP908H

1 8
Download 8 pages 42.45 Kb
Page 7
Image 7
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Attaching the Accessories to the Flexible Steam Hose

Dual Edge Glass & Tile Squeegee This attachment is very useful for cleaning large windows, plastic material, ceramic, tiled or marble surfaces.

To use: Connect the tile squeegee to the hand grip or use with extension tube for hard to reach surfaces.

Apply steam abundantly, rub with the soft spongy edge, then remove excess water and dirt with the glass wiping edge.

IMPORTANT:When cleaning windows, always avoid any sudden changes in temperature to prevent glass breakage or cracks.

Concentrator

Attach the concentrator to the handgrip or to the extension tubes. Then attach the detail brushes to the concentrator.

Detail Brush

It is best for cleaning grout in-between the tiles, ceramic and marble.

To use: Attach the detail brush on to the end of the concentrator, which then may be used directly

on the hand grip or with the extension tubes.

Tips On How To Use Your System

Water

Use tap water for all your cleaning needs.

However, if you live in an area with hard water, use de-mineralized / distilled water when steaming light colored fabrics to eliminate the possibility of hard water stains.

IMPORTANT: Do NOT add cleaning solutions, scented perfumes, oils or any other chemicals to the water used in this appliance. Use tap water or distilled/purified water if the tap water in your area is very hard.

WARNING: A towel wrapped around the brush can become hot enough to burn. Make sure that you let the towel cool off for 5 minutes before touching it.

Using Towels

For best results use 100% cotton white terry cloth towels.

Use correct size of towel to allow you to wrap the towel around the brushes and clip it under the spring loaded cloth holder.

The purpose of using a towel is to absorb moisture and dirt being removed. Always use dry towels. A wet towel will smear the dirt.

Wash towels with strong detergent and bleach.

Using scented fabric softener while washing the towels will cause the scent to be released into the air when using the towels with your steam system.

Efficient Work

For vertical surfaces, wipe with a towel from the top down, in this way the dirty water will not soil surfaces already cleaned.

Avoid changing brushes back and forth while cleaning.

Start with the smallest brush to clean tight spots and corners first.

Use a towel to wipe dirt as soon as possible, otherwise it will dry and re-adhere to the surface.

Components

Power “On” Light (red): This light will illuminate when the unit is plugged into the 120V. wall outlet and will remain on until the unit is unplugged.

CAUTION: Read the instructions for

“Filling the Water Tank” before opening the Safety Cap. Always depress hand grip steam trigger until all pressure/ steam has been vented from boiler.

CAUTION: Always unplug before filling. ALLOW UNIT TO COOL FOR

FIFTEEN (15) MINUTES BEFORE REFILLING.

IMPORTANT: Do NOT add cleaning solutions, scented perfumes, oils or any other chemicals to the water used in this appliance. Use tap water or distilled/purified water if the tap water in your area is very hard.

Filling Your Steam Cleaner With Water

IMPORTANT: Always insure that the unit is “UNPLUGGED” from the wall receptacle prior to initial filling or re-filling the water tank. Never attempt to fill this unit under a water tap, always use the filling funnel provided. Failure to follow these steps will cause the water tank to overfill and may pose an electrical safety hazard.

Step 1: Before filling the steam cleaner, make sure that the unit is NOT plugged in and has been allowed to cool for fifteen (15) minutes.

Step 2: Squeeze and hold handgrip trigger until all pressure has been released from the boiler. Turn Safety/Filler Cap counter clockwise until removed. (See caution above.)

Step 3: Place the appliance on a flat, stable surface and insert the funnel into the tank opening and add 40 US fl. oz. (1200 ml) of water.

(Fig. 1) Place the funnel in the tank opening as illustrated in Fig. 1. The funnel has been specially designed to show when the water tank is full. When water starts to come out of the vent hole of the funnel, the tank is full. Remove the funnel slowly and let the remaining water in it to go inside the water tank. Do Not Overfill. Replace the Safety Filler Cap.

Step 4: Connect desired attachments onto the Flexible Steam Hose.

Step 5: Plug the unit into a standard (120 volt, grounded) wall receptacle. Allow approximately 8-10 minutes for vapor to reach its working temperature and pressure. The green ready light will illuminate when the unit is ready for use.

Step 6: Upon initial use, some water will come out from the nozzle of the attachment. This is unvaporized water in the hose and is normal. Always point nozzle in a safe direction.

NOTE: When the steam cleaner has run out of water, steam output will cease.

WARNING: Always drain the condensed water from hose before use or if unit has been left idle for a period of time. To drain hose, direct nozzle into an appropriate container or sink and depress hand grip steam trigger. Once hose has been drained, normal use may be resumed. Never direct nozzle towards people, animals or plants.

Vent Hole

Fig. 1

WARNING: Allow unit to cool for 15 minutes before refilling. When refilling the steam cleaner while it is still hot, the first drops of water might bubble up. Use caution when opening the

Safety/Filler Cap as cap may become hot during use and escaping steam can cause scalding.