10 - COMMISSIONING YOURCONDITIONER
- Press the key to conrm the new setting,the display then returns to the new setting.
The setting can be adjusted between 9 and 15°C. Beyond this range,the and keys do not work.

WARNING: to operate correctly, your conditioner must be in a location where the ambient

temperature is between -5°C is 35°C.

When making signicant modications to temperature settings,it can take several hours for the temperature in your cellar to stabilise and for the conditioner
to display the desired temperature.

VI- Silent function

Your EuroCave conditioner is tted with a silent function which allows the sound level to be reduced when you enter the cellar.
When the conditioner is on:
- Press and hold down the key for 3 seconds.
The display then appears. N ext the current temperature is displayed.
You will be able to see this function via the pictogram which ashes for 15 minutes.
The compressor then remains in operation and the fans change to slow speed for 15 minutes.
After this,the conditioner returns to the default operating speed.

VII- H eating function

The EuroCave IN OA conditioner has a heater (650 W ) allowing the internal temperature in your cellar to be maintained at an optimal level.
As soon as the temperature drops below the programmed temperature,the heating function is automatically activated.

VIII- C hanging the remote control batter ies

Remote control power supply:1 x 3 V (CR 2430 battery) (2 batteries supplied)
Battery life:2 years approx
The remote control is supplied with 2 batteries.O nly one battery is required (pull o the plastic strip to make it
useable).The other battery is a spare.
- When the battery runs out, the pictogram ashes on the remote control’s display.
- Take the remote control o the wall.
- On the back of the remote control, push the used battery down using a screwdriver (see diagram opposite).
- Pull the strip from the spare battery, which will then be ready for use.
- Remember to buy a replacement for the spare battery.

IX- Dischar ging condensate

Your conditioner was designed to allow condensate to be discharged (discharge pipe located under the conditioner’s
housing) either inside the cellar,if the humidity level is too low,or outside the cellar.
Simply pass the pipe through the wall to discharge the condensate into the room next to the conditioner housing.
Ensure that the piping is not kinked.
20