MENU
6.10 CONTROL SETTING MENU
CONTROL SETTING MENU
RS232 BAUD RATE | : 9600 BPS |
RS232 STOP BIT | : 1 |
RS232 PARITY | : NONE |
RS232 DATA BIT | : 8 |
RS485 BAUD RATE | : 9600 BPS |
RS485 STOP BIT | : 1 |
RS485 PARITY | : NONE |
RS485 DATA BIT | : 8 |
RS232/RS485 ID | : 1 |
In the CONTROL SETTING MENU, we define
(1)RS232 BAUD RATE: There are 6 different speeds that can be used to transmit instruction or information through the RS232 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 3840 baud. The default setting from the factory is 9600 baud.
(2)RS232 STOP BIT: Select stop bit: 1 or 2
(3)RS232 PARITY: Select parity mode: NONE/ODD/EVEN
(4)RS232 DATA BIT: Select data bit : 8 or 7
(5)RS485 BAUD RATE: There are 6 different speeds that can be used to transmit instruction or information through the RS485 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 3840 baud.
(6)RS485 STOP BIT: Select stop bit: 1 or 2
(7)RS485 PARITY:Select parity lever: NONE/ODE/EVEN
(8)RS485 DATA BIT: Select data bit : 8 or 7
(9)RS232/RS485 ID: RS232/RS485 address.The adress range for the DVR: 1~200.
NOTE: Settings for remote keyboards
Turn the JOG dial clockwise or
Press ENTER key to confirm the option and move to next column.
ENTER
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU
21