EverFocus EFC--02-1-A user manual Connection to Request-to-Exit, Connection to Fire & Alarm Input

Models: EFC--02-1-A

1 75
Download 75 pages 61.31 Kb
Page 28
Image 28

NOTE: Among these four terminals, terminal 9 and 25 are GND, shared by the door sensor and request-to exit (10 and 26 are your input signals)

Connection to Request-to-Exit

The door module also provides an interface to the request-to-exit button or sensor. Door 1 is connected to terminals 8-9 and door 2 is connected to terminals 24-25 respectively.

(24)8

(25)9

Door module

EXIT

Fig. 2.13 Connecting REX to Controller

Terminals 8 ~9 are for Door 1 and terminals 24~25 are for Door 2 connections.

NOTE: Among these four terminals, terminal 9 and 25 are GND, shared by the door sensor and request-to exit (8 and 24 are your input signals)

Connection to Fire & Alarm Input 0

The main module provides fire alarm input and one general alarm input (alarm input 0), connecting to terminal 1, 2 and 2, 3 respectively. The GND (terminal is shared by these two input signals.

Connection to Alarm Input

The alarm signals other than the fire alarm and alarm input 0 are controlled by the alarm module, which contains 8 alarm inputs and 8 alarm outputs. Using the 5th channel alarm signal input as an example, the method to connect the alarm module to the alarm sensor is shown in Fig. 2.14: